NextSDS Logo
Safety Data Sheet EN

Intergard 410 Part B

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Intergard 410 Part B
Product Code
EMA080

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use, Industrial use. Product use : Two component coating for interior and exterior use.

Uses advised against

All other uses

Manufacturers & Suppliers

I

International Färg AB

manufacturer

Holmedalen 3, Aspereds Industriomrade, SE-424 22 Angered, Sweden

+46 (0) 31 928500

I

International Paint Ltd.

manufacturer

Stoneygate Lane, Felling, Gateshead, Tyne and Wear, NE10 0JY UK

+44 (0)191 469 6111

Emergency Contacts

National advisory body/Poison Center

+44 (0)344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Corr. Cat. 1C H314
Eye Dam. Cat. 1 H318
Skin Sens. Cat. 1 H317
STOT SE Cat. 3 H335
STOT RE Cat. 2 H373
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H226 Flammable liquid and vapor.
H314 Causes severe skin burns and eye damage.
H317 May cause an allergic skin reaction.
H335 May cause respiratory irritation.
H373 May cause damage to organs through prolonged or repeated exposure.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof electrical, ventilating or lighting equipment.
P243 Take action to prevent static discharges.
P260 Do not breathe vapor.
P273 Avoid release to the environment.
P280 Wear protective gloves, protective clothing and eye or face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P303 + P361 + P353 + P310 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water. Immediately call a POISON CENTER or doctor.
P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor.
P333 + P313 If skin irritation or rash occurs: Get medical advice or attention.
P363 Wash contaminated clothing before reuse.
P370 + P378 In case of fire: Use water spray, dry chemical powder or carbon dioxide to extinguish.
P391 Collect spillage.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Keep cool.
P501 Dispose of contents and container in accordance with all local, regional, national or international regulations.
IF INHALED: Immediately call a POISON CENTER or doctor.
IF SWALLOWED: Immediately call a POISON CENTER or doctor. Rinse mouth. Do NOT induce vomiting.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Fatty acids, C18-unsatd., dimers, oligomeric reaction products with tall-oil fatty acids and triethylenetetramine EC: 500-191-5 68082-29-1 50 - 75% Yes
Reaction mass of ethylbenzene and xylene EC: 905-588-0 --- 25 - 50% Yes
2,4,6-tris (dimethylaminomethyl) phenol EC: 202-013-9 90-72-2 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: mucous membrane and respiratory system irritation, headache, dizziness, fatigue, muscular weakness, drowsiness, loss of consciousness, respiratory tract irritation, coughing

Skin contact

Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: removal of natural fat from the skin, non-allergic contact dermatitis, absorption through the skin, pain or irritation, redness, blistering

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses if easy to do. Continue to rinse for at least 10 minutes.

Symptoms: irritation, reversible damage, pain, watering, redness

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: nausea, diarrhea, vomiting, stomach pains

Immediate Medical Attention

Get medical attention immediately. Call a poison center or physician. Chemical burns must be treated promptly by a physician.

Medical Treatment

Chemical burns must be treated promptly by a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Never use water for extinction.

Specific hazards

Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. This material is toxic to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant.

Materials: inert dry material, sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

Storage

Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. To avoid fire or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before transferring material.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time >480 minutes according to EN374) is recommended. Recommended gloves: Viton ® or Nitrile, thickness ≥ 0.38 mm. When only brief contact is expected, a glove with protection class of 2 or higher (breakthrough time >30 minutes according to EN374) is recommended. Recommended gloves: Nitrile, thickness ≥ 0.12 mm. Gloves should be replaced regularly and if there is any sign of damage to the glove material.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles and/or face shield. If inhalation hazards exist, a full-face respirator may be required instead.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Wear a respirator conforming to EN140 with type A/P2 filter or better. Dry sanding, flame cutting and/or welding of the dry paint film will give rise to dust and/or hazardous fumes. Wet sanding/flatting should be used wherever possible. If exposure cannot be avoided by the provision of local exhaust ventilation, suitable respiratory protective equipment should be used.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
Not available.
Vapor Pressure
Reaction mass of ethylbenzene and xylene: 6.7 mm Hg (0.89 kPa); 2,4,6-tris(dimethylaminomethyl) phenol: 0.056 mm Hg (0.0075 kPa); Fatty acids, C18-unsatd., dimers, oligomeric reaction products with tall-oil fatty acids and triethylenetetramine: 0 mm Hg (0 kPa)
Upper Explosive Limit
Greatest known range: Upper: 6.7% (xylene)
Metal Corrosion
---
Lower Explosive Limit
Greatest known range: Lower: 0.8% (xylene)
Physical State Data
liquid
Cloud Point
---
Physical State
Liquid.
Freezing Point
---
State Under Standard Conditions
---
Colour
Colorless.
Ph
Not applicable. [DIN EN 1262]
Solubility In Fat
---
Crystallisation Point
---
Solubility
Not soluble [OESO (TG 105)]
Evaporation Rate
---
Form
---
Voc Content
---
Kinematic Viscosity
Kinematic (room temperature): 107 mm²/s [DIN EN ISO 3219] Kinematic (40°C): 100 mm²/s [DIN EN ISO 3219]
Bulk Density
---
Dynamic Viscosity
---
Flash Point
Closed cup: 29°C (84.2°F) [Pensky-Martens]
Solidification Point
---
Vapor Density
Not available.
Density
0.933 g/cm³ [DIN EN ISO 2811-1]
Explosive Limits
---
Flammability
---
Decomposition Temperature
Not available.
Relative Evaporation Rate
---
Melting Point
Not available.
Boiling Point
136°C (276.8°F)
Odor
Amine-like.
Auto Ignition Temperature
2,4,6-tris(dimethylaminomethyl)phenol: 382°C (719.6°F); Fatty acids, C18-unsatd., dimers, oligomeric reaction products with tall-oil fatty acids and triethylenetetramine: 401°C (753.8°F); Reaction mass of ethylbenzene and xylene: 432°C (809.6°F)
Partition Coefficient
Not applicable.
Colour Intensity
---
Properties Status
---
Appearance
Colorless.
Softening Point
---
Relative Density
---
Solubility In Water
---
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

oxidizing materials

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3469
Shipping Name
PAINT, FLAMMABLE, CORROSIVE
Transport Class
3 (8)
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Intergard 410 Part B?

The signal word is danger.

What is the physical form of Intergard 410 Part B?

Intergard 410 Part B is a liquid. appearing as colorless. with colorless. color. It has amine-like. odor.

What is the solubility of Intergard 410 Part B?

Not soluble [OESO (TG 105)]

What is Intergard 410 Part B used for?

Professional use, Industrial use. Product use : Two component coating for interior and exterior use.

What are the hazard statements for Intergard 410 Part B?

This substance has 6 hazard statements:

  • H226: Flammable liquid and vapor.
  • H314: Causes severe skin burns and eye damage.
  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.
  • H373: May cause damage to organs through prolonged or repeated exposure.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Intergard 410 Part B?