Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Neutralyte N2
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
substance for electrochemical grid marking of metal plates
Uses advised against
No information available.
Manufacturers & Suppliers
ViALUX Messtechnik + Bildverarbeitung GmbH
manufacturer
Am Erlenwald 10, D-09128 Chemnitz
+49 (3 71) 33 42 47-0
Emergency Contacts
Emergency Contact
+49 (3 71) 33 42 47-0
Monday - Friday 8 a.m. - 5 p.m.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air.
Wash with plenty of water. Immediately remove any contaminated clothing, shoes or stockings.
Rinse immediately carefully and thoroughly with eye-bath or water. In case of contact with eyes, rinse immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart.
If accidentally swallowed rinse the mouth with plenty of water (only if the person is conscious).
Immediate Medical Attention
Medical treatment necessary for inhalation and skin contact. Consult an ophthalmologist for eye contact. Obtain immediate medical attention for ingestion.
Medical Treatment
Medical treatment necessary.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray jet, Foam, Dry extinguishing powder
Full water jet
Non-flammable. Thermal decomposition can lead to the escape of irritating gases and vapours.
Use water spray jet to protect personnel and to cool endangered containers. Suppress gases/vapours/mists with water spray jet. Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Provide adequate ventilation. Do not breathe gas/fumes/vapour/spray. Avoid contact with skin, eyes and clothes. Use personal protection equipment.
Do not allow to enter into surface water or drains.
Wipe up with absorbent material (eg. cloth, fleece). Clear contaminated areas thoroughly.
Materials: cloth, fleece
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
If handled uncovered, arrangements with local exhaust ventilation have to be used. Do not breathe gas/fumes/vapour/spray. Do not dry up the product.
Keep container tightly closed. Keep locked up. Store in a place accessible by authorized persons only.
Remove contaminated, saturated clothing immediately. Draw up and observe skin protection programme. Wash hands and face before breaks and after work and take a shower if necessary. When using do not eat, drink, smoke, sniff.
No special fire protection measures are necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
If handled uncovered, arrangements with local exhaust ventilation have to be used. Do not breathe gas/fumes/vapour/spray. Provide adequate ventilation as well as local exhaustion at critical locations.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Suitable material: NBR (Nitrile rubber)
Wear eye/face protection.
In case of inadequate ventilation wear respiratory protection. At emergence of dried solid residues use particle filter P2.
Use of protective clothing. Material, alkali-resistant
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under storage at normal ambient temperatures.
No hazardous reaction when handled and stored according to provisions.
No known hazardous reactions.
No information available.
In case of fire may be liberated: nitrogen oxides (NOx). Hydrogen chloride (HCl)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Neutralyte N2?
The signal word is danger.
What is the physical form of Neutralyte N2?
Neutralyte N2 is a liquid with light blue color. It has neutral odor.
What is Neutralyte N2 used for?
substance for electrochemical grid marking of metal plates
What are the hazard statements for Neutralyte N2?
This substance has 1 hazard statement:
- H360FD: May damage fertility. May damage the unborn child.
What is the melting point of Neutralyte N2?
The melting point is not determined and the boiling point is not determined.