Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Electrolyte E1
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
substance for electrochemical grid marking of metal plates
Uses advised against
No information available.
Manufacturers & Suppliers
ViALUX Messtechnik + Bildverarbeitung GmbH
manufacturer
Am Erlenwald 10, D-09128 Chemnitz
+49 (3 71) 33 42 47-0
Emergency Contacts
Emergency Contact
+49 (3 71) 33 42 47-0
Monday - Friday 8 a.m. - 5 p.m.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethylenediaminetetraacetic acid di-Na salt x 2 H2O | 6381-92-6 | 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air.
Wash with plenty of water. Take off contaminated clothing and wash it before reuse.
In case of contact with eyes, rinse immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart.
Rinse mouth immediately and drink 1 glass of of water.
Immediate Medical Attention
Subsequently consult an ophthalmologist.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray jet, Foam, Dry extinguishing powder
Full water jet
Thermal decomposition can lead to the escape of irritating gases and vapours.
Co-ordinate fire-fighting measures to the fire surroundings.
Firefighter Protection
Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection equipment. Provide fresh air.
Do not allow to enter into surface water or drains.
Wipe up with absorbent material (eg. cloth, fleece). Clear contaminated areas thoroughly.
Materials: absorbent material (eg. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures are necessary.
Keep container tightly closed.
Take off contaminated clothing. Wash hands before breaks and after work. When using do not eat, drink, smoke, sniff.
No special fire protection measures are necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation as well as local exhaustion at critical locations. Suitable floor material: alkali-resistant.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Suitable material: NBR (Nitrile rubber)
Wear eye/face protection.
In case of inadequate ventilation wear respiratory protection. At emergence of dried solid residues use particle filter P2.
Use of protective clothing. Material, alkali-resistant
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under storage at normal ambient temperatures.
No hazardous reaction when handled and stored according to provisions.
No known hazardous reactions.
No information available.
No information available.
No known hazardous decomposition products. In case of fire may be liberated: nitrogen oxides (NOx). Hydrogen chloride (HCl)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Electrolyte E1?
The signal word is no signal word.
What is the physical form of Electrolyte E1?
Electrolyte E1 is a liquid with yellow-green color. It has neutral odor.
What is Electrolyte E1 used for?
substance for electrochemical grid marking of metal plates
What is the melting point of Electrolyte E1?
The melting point is not determined and the boiling point is not determined.