Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CHLORIDE ANALYSER BUFFER
- Product Code
- 00156208
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Chemical for industrial and laboratory use. Not suitable for domestic use.
Manufacturers & Suppliers
Sherwood Scientific Ltd
manufacturer
1 The Paddocks, Cherry Hinton Road, Cambridge, CB1 8DH, UNITED KINGDOM
+44(0)1223 243444
Emergency Contacts
Emergency Contact
01223 243444
08:00 – 16:30
Emergency Contact
112
24hr
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetic acid EC: 200-580-7 | 64-19-7 | 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from exposure. Keep warm and at rest. If there is difficulty in breathing give oxygen if available.
Wash off skin thoroughly with water. Remove contaminated clothing immediately and wash before re-use.
Irrigate thoroughly with plenty of water for at least 10 minutes, holding the eye open.
If conscious give plenty of water to drink. Do not induce vomiting. If there is difficulty in breathing give oxygen if available. If breathing stops or shows signs of failing, apply artificial resuscitation. If unconscious place in the recovery position.
Immediate Medical Attention
OBTAIN MEDICAL ATTENTION URGENTLY (Eyes, Ingestion). If discomfort persists OBTAIN MEDICAL ATTENTION (Skin, Inhalation).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, alcohol resistant foam, dry powder or carbon dioxide.
Do not use water jet.
Presents no specific fire danger.
Use water spray to keep fire exposed containers cool.
Firefighter Protection
Fire-fighters should wear protective clothing and breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area immediately. Do not allow general use of area until it is safe to do so.
Wash area down with copious amounts of water.
Contain and absorb on inert material. Transfer absorbent to salvage container for removal. Wash area down with copious amounts of water.
Keep material out of sewers, storm drains, surface waters and soil.
Transfer absorbent to salvage container for removal. Wash area down with copious amounts of water.
Materials: inert material
Related Products
Similar products with comparable safety profiles
CHLORIDE ANALYSER BUFFER
---
CHLORIDE ISE STANDARD
---
CHLORIDE METER M926S STANDARD 100mmol/l Cl
---
CHLORIDE METER Mg26S STANDARD 100mmol/l Cl
---
ChloroChek® Reagent, Buffer solution
---
SODIUM CHLORIDE
CAS: 7647-14-5
SODIUM CHLORIDE
---
SODIUM HYPOCHLORITE SOLUTION
CAS: 7681-52-9
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Do not breath vapours. Do not allow to contaminate clothing.
Well ventilated, cool, dry storage.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use L.E.V. or natural ventilation to maintain vapour concentrations below exposure limits.
Use nitrile gloves or PVC gauntlets.
Use chemical full face shield.
If not, use a well maintained chemical cartridge organic vapour respirator, or use self-contained breathing apparatus.
Wear PVC oversuit.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
No data available.
No data available.
No specific conditions.
Hydrogen peroxide, chromium trioxide and potassium permanganate. Potassium t-butoxide. Alkalis.
None unusual. Burning will produce smoke, carbon monoxide and/or carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.2 Persistence and degradability
No data available.
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT & vPvB Assessment
Assessment not required.
12.6 Other adverse effects
None known at present.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dilute in a large excess of water and carefully neutralise with soda ash, then wash to drain with copious amounts of water.
Dilute in a large excess of water and carefully neutralise with soda ash, then wash to drain with copious amounts of water.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CHLORIDE ANALYSER BUFFER?
The signal word is warning.
What is the physical form of CHLORIDE ANALYSER BUFFER?
CHLORIDE ANALYSER BUFFER is a liquid appearing as clear colourless liquid. with colourless color. It has sharp vinegary odour and burning taste. odor.
What is CHLORIDE ANALYSER BUFFER used for?
Chemical for industrial and laboratory use. Not suitable for domestic use.
What are the hazard statements for CHLORIDE ANALYSER BUFFER?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of CHLORIDE ANALYSER BUFFER?
The melting point is Not applicable and the boiling point is Not available.