NextSDS Logo
Safety Data Sheet EN

Rigicon

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Rigicon

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Auxiliary for the textile industry, auxiliary for the paper industry

Manufacturers & Suppliers

INSULCON B.V. logo

INSULCON B.V.

manufacturer

Zilverhoek 4, 4651 SP STEENBERGEN, The Netherlands

+31 (0)167-565750

http://www.insulcon.com

K

KERAMAB N.V.

+32 (0)3 711.02.78

I

INSULCON GMBH

+49 (0) 2162 249 60-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Colloidal suspension of amorphous silica, stabilized in an ACID MEDIUM. Free from crystalline silica. SiO^2 content: approx. 30%.

Chemical Name CAS Number Concentration Hazardous
amorphous silica --- 30% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In the event of symptoms bring the patient to fresh air.

Skin contact

In case of contact with skin wash off immediately with plenty of water. Consult a doctor if skin irritation persists.

Eye contact

Rinse the affected eye immediately with plenty of water at the same time keep the unaffected eye well protected.

Ingestion

In case of problems seek medical advice and show the package or label.

Immediate Medical Attention

If someone exposed to the product feels unwell, contact a doctor and show this safety data sheet.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray jet, Foam, Dry powder, Carbon dioxide. Product itself is non-combustible; Fire extinguishing method of surrounding areas must be discussed.

Firefighter Protection

Well closed full protective clothing (coat and pants) including helmet. Use-self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow entry to drains, water courses or soil.

Cleanup methods

Pick up with liquid binding materials and if necessary fill in containers capable of being locked. Containers in which spilt substance has been collected must be adequately labelled. Clean contaminated floors and objects thoroughly, observing environmental regulations.

Materials: liquid binding materials

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear respiratory protection when spraying.

Storage

Keep only in unopened original container. Protect against frost. Keep container tightly closed and dry in a cool, well-ventilated place.

Fire prevention

Observe the general rules of industrial fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

See chapter 7; no measures exceeding the ones mentioned are necessary.

Hands

For short-term exposure (splash protection): - Nitrile rubber gloves. - Minimum breakthrough time / gloves: > 10 min - Minimum thickness / gloves > 0,4 mm These types of protective gloves are offered by various manufacturers. Please note the manufacturers' detailed statements, especially about the minimum thickness and the minimum breakthrough time. Consider also the particular working conditions under which the gloves are being used.

Eyes

Tightly fitting safety glasses.

Respiratory

Use respiratory protection in case of insufficient exhaust ventilation or prolonged exposure

Skin/Body

Protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid, Milky white
Colour
Milky white
Colour Intensity
---
Form
Liquid
Odor
Odourless
Odor Threshold
---
Ph
3,5 – 4,5 at (20°C)
Melting Point
---
Boiling Point
Note: not determined
Flash Point
Note: not applicable
Freezing Point
---
Softening Point
---
Solidification Point
From 0°C
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Note: not determined
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,19 – 1,21 g/cm³ at 20°C
Flammability
---
Upper Explosive Limit
Note: not determined
Lower Explosive Limit
Note: not determined
Explosive Limits
---
Auto Ignition Temperature
Note: not determined
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Note: not reasonable
Solubility In Water
Note, miscible in all proportions
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Note: not determined
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

When handled and stored appropriately no dangerous reactions are known.

Decomposition

When handled and stored appropriately no dangerous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Rigicon?

The signal word is no signal word.

What is the physical form of Rigicon?

Rigicon is a liquid appearing as liquid, milky white with milky white color. It has odourless odor.

What is Rigicon used for?

Auxiliary for the textile industry, auxiliary for the paper industry