Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ClearKlens IPA VH1
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 9FYG-V1JC-F003-5HU7
Identified Uses
Surface disinfectant. for general surface disinfection For professional and industrial use only.
Uses advised against
Uses other than those identified are not recommended.
Manufacturers & Suppliers
Diversey Europe Operations BV
manufacturer
De Corridor 4, 3621ZB Breukelen [Maarssenbroeksedijk 2, 3542DN Utrecht], The Netherlands
Diversey Belgium
national supplier
Haachtsesteenweg 672, 1910 Kampenhout, België / Belgique / Belgien
016-617777
Emergency Contacts
Antigifcentrum / Centre Antipoisons / Antigiftzentrum
070-245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propan-2-ol EC: 200-661-7 | 67-63-0 | 50 - 75% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing.
Symptoms: May cause drowsiness or dizziness.
Wash skin with plenty of lukewarm, gently flowing water. Take off immediately all contaminated clothing and wash it before reuse.
Symptoms: Irritation
Hold eyelids apart and flush eyes with plenty of lukewarm water for at least 15 minutes. Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Symptoms: Irritation
Rinse mouth. Immediately drink 1 glass of water. Never give anything by mouth to an unconscious person.
Symptoms: No known effects or symptoms in normal use.
Immediate Medical Attention
Get medical attention or advice if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide. Dry powder. Water spray jet. Fight larger fires with water spray jet or alcohol-resistant foam.
No special hazards known.
Firefighter Protection
As in any fire, wear self contained breathing apparatus and suitable protective clothing including gloves and eye/face protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dyke to collect large liquid spills.
Do not allow to enter drainage system, surface or ground water. Dilute with plenty of water.
Absorb with liquid-binding material. Collect in closed and suitable containers for disposal.
Materials: sand, diatomite, universal binders
Related Products
Similar products with comparable safety profiles
ClearKlens Multi VH46
UFI: E3G1-K077-200N-WQDE
ClearKlens Solve VH21
UFI: W0E2-A1HC-J00N-VT79
ClearKlens Power VH22
UFI: U7V0-70CV-P00S-DM67
Clearklens Brite VH3
UFI: 3JE5-A0G9-U00C-6HCE
ClearKlens ECO VH39
UFI: SEPH-F17Y-U00S-HX0R
Clearklens Flow VH20
UFI: DAF5-V0PV-K00T-4KM0
ClearKlens Oxifast
UFI: UJY2-D0MY-S00D-SDNA
VisionAid Anti-fog/Anti-static Lens Cleaner, Clear
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not mix with other products unless advised by Diversey. Wash hands before breaks and at the end of workday. Store used personal protective equipment separately. Avoid contact with skin and eyes. Do not breathe vapours. Do not breathe spray.
Store in a well-ventilated place. Store in a closed container. Keep only in original packaging. Keep from freezing. Keep cool. Keep away from heat and direct sunlight. Keep at temperature not exceeding 30 °C.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Wash hands before breaks and at the end of workday. Store used personal protective equipment separately.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Apply the product only in a sufficiently ventilated room. The minimum air change rates required are: - 8/h in laboratories; - 60/h in pharmaceutical and cosmetics manufacturing facilities; - 150/h in cleanrooms.
Chemical-resistant protective gloves (EN 374). Verify instructions regarding permeability and breakthrough time, as provided by the gloves supplier. Consider specific local use conditions, such as risk of splashes, cuts, contact time and temperature. Suggested gloves for prolonged contact: Material: butyl rubber Penetration time: ≥ 480 min Material thickness: ≥ 0.7 mm Suggested gloves for protection against splashes: Material: nitrile rubber Penetration time: ≥ 30 min Material thickness: ≥ 0.4 mm In consultation with the supplier of protective gloves a different type providing similar protection may be chosen.
Safety glasses are not normally required. However, their use is recommended in those cases where splashes may occur when handling the product (EN 16321).
Respiratory protection is not normally required. However, inhalation of vapour, spray, gas or aerosols should be avoided.
No special requirements under normal use conditions.
Should not reach sewage water or drainage ditch undiluted or unneutralised.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal storage and use conditions.
No reactivity hazards known under normal storage and use conditions.
No hazardous reactions known under normal storage and use conditions.
None known under normal storage and use conditions.
None known under normal use conditions.
None known under normal storage and use conditions.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1219
- Shipping Name
- Isopropanol (isopropyl alcohol), solution
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ClearKlens IPA VH1?
The signal word is danger.
What is the physical form of ClearKlens IPA VH1?
ClearKlens IPA VH1 is a liquid with clear, colourless color. It has product specific odor.
What is ClearKlens IPA VH1 used for?
Surface disinfectant. for general surface disinfection For professional and industrial use only.
What are the hazard statements for ClearKlens IPA VH1?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of ClearKlens IPA VH1?
The melting point is -88 °C and the boiling point is > 82.5 °C.