Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FLOWBUILD COVE F PART A
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- FGH0-A025-T003-UWV9
Identified Uses
Manual activities involving hand contact. Widespread use leading to inclusion into/ onto article (indoor). For use by appropriately trained applicators. Roller application or brushing. Low energy spreading of coatings. Component of multicomponent coatings - Industrial and professional use.
Uses advised against
Home DIY applications, because of the health hazards and training required. others than recommended
Manufacturers & Suppliers
Construction Products Group
Tremco CPG Poland Sp. z o. o.
manufacturer
Ul. Marywilska 34, 03-228 Warszawa, Polska
+48 22 879 8907
http://www.flowcrete.com.pl/
Emergency Contacts
CHEMTREC
+1 703 5273887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| bis[4-(2,3-epoxypropoxy) phenyl]propane EC: 216-823-5 | 1675-54-3 | 2.5 - 10% | Yes |
| henyleneoxymethylene)]bis (oxirane) and 2,2'-[methylenebis EC: 701-263-0 | --- | 1 - 2.5% | Yes |
| Oxirane, mono[(C12-14-alkyloxy)methyl] derivs. EC: 271-846-8 | 68609-97-2 | 1 - 2.5% | Yes |
| Quaternary ammonium compounds, benzyl-C14-18-alkyldimethyl, chlorides | 68390-98-7 | 0.1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Keep respiratory tract clear. Remove person to fresh air. If signs/symptoms continue, get medical attention.
Use a mild soap if available. Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. If skin irritation persists, call a physician.
Keep eye wide open while rinsing. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses. If eye irritation persists, consult a specialist.
Gently wipe or rinse the inside of the mouth with water. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person. If swallowed, seek medical advice immediately and show this container or label.
Immediate Medical Attention
If signs/symptoms continue, get medical attention. If skin irritation persists, call a physician. If eye irritation persists, consult a specialist. If swallowed, seek medical advice immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon Dioxide, Dry Chemical, Foam, Water Fog
Alcohol, Alcohol based solutions, any other media not listed above.
In case of fire hazardous decomposition products may be produced such as: Carbon dioxide (CO2), carbon monoxide (CO), oxides of nitrogen (NOx), dense black smoke.
Keep containers and surroundings cool with water spray.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep people away from and upwind of spill/leak.
Do not allow material to contaminate ground water system. Prevent product from entering drains. May cause long-term adverse effects in the aquatic environment.
soak up with non-combustible absorbent material and transfer to a container for disposal
Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Flowbuild Cove F Part B
UFI: DS30-D0WE-F00V-XDMR
Flow improver FI 3710
---
Flowcoat SF41 LE Part A
UFI: Q862-A02M-F003-QEGS
Peran/Flowshield SL Part A
UFI: XYX0-K07J-U00D-P5M0
Flowshield LXP HD Filler C
CAS: 14808-60-7
Ucrete® PT5 TZ Cove Part 5
---
SEAL & BOND MS CONSTRUCT
---
Flowcoat SF41 LE Part B
UFI: G662-T0D7-400M-12WQ
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment. Use only in well-ventilated areas. Do not breathe vapours or spray mist. Avoid contact with skin and eyes.
Keep at temperatures between 5 and 25 °C. Do not freeze. Store at room temperature in the original container. Keep locked up or in an area accessible only to qualified or authorised persons. Keep container closed when not in use. Store in a dry, well ventilated place away from sources of heat, ignition and direct sunlight.
Handle in accordance with good industrial hygiene and safety practice. Keep working clothes separately. Keep away from food, drink and animal feedingstuffs. When using, do not eat, drink or smoke. Wash hands and face before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
As a rule, at least 5 air changes per hour are recommended at the workplace. Ensure adequate ventilation, especially in confined areas.
Impervious gloves. Chemical resistant gloves made of butyl rubber or nitrile rubber category III according to EN 374. Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).
Eye wash bottle with pure water. Tightly fitting safety goggles. If splashes are likely to occur, wear: Face-shield, tightly fitting safety goggles (EN 166).
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Wear a positive-pressure supplied-air respirator. In case of insufficient ventilation and where workplace exposure limits may be exceeded, wear suitable respiratory equipment. Respirator with filter for organic vapor. Recommended Filter type: A2, EN 136/140/145/143/149
Long sleeved clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if stored and applied as directed. Stable under normal conditions.
No reactivity hazards known under normal storage and use conditions.
Hazardous polymerisation does not occur.
Do not freeze.
oxidising agents, strongly alkaline and strongly acid materials, Strong oxidizing agents, Copper alloys, Copper, radical-forming starting agents, peroxides, reactive metals, Halogenated hydrocarbons.
In case of fire hazardous decomposition products may be produced such as: Carbon dioxide (CO2), carbon monoxide (CO), oxides of nitrogen (NOx), dense black smoke.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FLOWBUILD COVE F PART A?
The signal word is warning.
What is the physical form of FLOWBUILD COVE F PART A?
FLOWBUILD COVE F PART A is a no information with not determined color. It has no information odor.
What is FLOWBUILD COVE F PART A used for?
Manual activities involving hand contact. Widespread use leading to inclusion into/ onto article (indoor). For use by appropriately trained applicators. Roller application or brushing. Low energy spreading of coatings. Component of multicomponent coatings - Industrial and professional use.
What are the hazard statements for FLOWBUILD COVE F PART A?
This substance has 3 hazard statements:
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of FLOWBUILD COVE F PART A?
The melting point is Not determined and the boiling point is N.D. - N.D..