Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- OK Autrod 2209
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Arc Welding
Manufacturers & Suppliers
ESAB Welding & Cutting Products
manufacturer
801 Wilson Ave., Hanover, PA 17331, USA
1-717-637-8911
http://www.esabna.com
ESAB
Emergency Contacts
Emergency Contact
+1 703-741-5970
Available outside office hours
Emergency Contact
1-800-424-9300
Available outside office hours
American Association of Poison Control Centers
1-800-222-1222
American Association of Poison Control Centers
+56 2 2 247 3600
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| IRON EC: 231-096-4 | 7439-89-6 | 60 - 70% | No |
| CHROMIUM EC: 231-157-5 | 7440-47-3 | 20 - 30% | No |
| Nickel powder EC: 231-111-4 | 7440-02-0 | 5 - 10% | Yes |
| MOLYBDENUM EC: 231-107-2 | 7439-98-7 | 2 - 5% | No |
| MANGANESE EC: 231-105-1 | 7439-96-5 | 1 - 2% | No |
| SILICON. EC: 231-130-8 | 7440-21-3 | 1% | No |
| COBALT EC: 231-158-0 | 7440-48-4 | 0.5% | Yes |
| COPPER EC: 231-159-6 | 7440-50-8 | 0.5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing has stopped, perform artificial respiration and obtain medical assistance immediately! If breathing is difficult, provide fresh air and call physician.
For skin burns from arc radiation, promptly flush with cold water. Get medical attention for burns or irritations that persist. To remove dust or particles wash with mild soap and water.
For radiation burns due to arc flash, see physician. To remove dusts or fumes flush with water for at least fifteen minutes. If irritation persists, obtain medical assistance.
Immediate Medical Attention
Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No specific recommendations for welding consumables. Welding arcs and sparks can ignite combustible and flammable materials. Use the extinguishing media recommended for the burning materials and fire situation.
No data available
Firefighter Protection
Wear self-contained breathing apparatus as fumes or vapors may be harmful.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to section 13.
Solid objects may be picked up and placed into a container. Liquids or pastes should be scooped up and placed into a container.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle with care to avoid stings and cuts. Wear gloves when handling welding consumables. Avoid exposure to dust. Do not ingest. Some individuals can develop an allergic reaction to certain materials. Retain all warning and identity labels.
Keep separate from chemical substances like acids and strong bases, which could cause chemical reactions.
Do not ingest.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Type B gloves are recommended when high dexterity is required as for TIG welding, while type A gloves are recommended for other welding processes. The contact temp (oC) is 100 and the threshold time (seconds) >15. Abrasion (Cycles):(Type A-2 (500));(Type B-1 (100)); Cut (Factor):(Type A-1 (1.2));(Type B-1 (1.2)); Tear (Newton):(Type A-2 (25));(Type B-1 (10)); Puncture (Newton):(Type A-2 (60));(Type B-1 (20)); Burning Behaviour:(Type A-3);(Type B-2); Contact Heat:(Type A-1);(Type B-1); Convective Heat:(Type A-2);(Type B--); Small Splashes:(Type A-3);(Type B-2); Dexterity:(Type A-1 (11));(Type B-4 (6.5))
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions
Non Reactive unless gets in contact with chemical substances like acids or strong bases could cause generation of gas
No data available
This product is only intended for normal welding purposes.
No data available
When this product is used in a welding process, hazardous decomposition products would include those from the volatilization, reaction or oxidation of the materials listed in Section 3 and those from the base metal / Coated wire / Coated rod / Bare wire / Bare rod. A significant amount of the chromium in the fumes can be hexavalent chromium. Manganese and nickel also have low exposure limits. Reasonably expected gaseous products would include carbon oxides, nitrogen oxides and ozone.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for OK Autrod 2209?
The signal word is no signal word.
What is the physical form of OK Autrod 2209?
OK Autrod 2209 is a solid, non-volatile with varying color. with no data available color. It has no data available odor.
What is the solubility of OK Autrod 2209?
No data available
What is OK Autrod 2209 used for?
Arc Welding
What is the melting point of OK Autrod 2209?
The melting point is >1000°C / >1800°F and the boiling point is No data available.