Product Information

Product Name
AMP Concrete & Masonry Self-Leveling Sealant - Gray
Product Code
070798007642

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Caulking Compound

Manufacturers & Suppliers

D

DAP Global Inc.

manufacturer

2400 Boston Street Suite 200 Baltimore, MD 21224-4723

888-327-8477

Emergency Contacts

Transportation

1-800-535-5053

Transportation

1-352-323-3500

Poison Control

1-800-222-1222

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Not a hazardous substance or mixture.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Limestone 1317-65-3 30 - 60% No
1,2-Benzenedicarboxylic acid, di-C9-C11-branched 68515-49-1 10 - 30% Yes
Organosilane Ester 2768-02-7 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If you experience difficulty in breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.

Skin contact

Wash skin with soap and water for 15 minutes. Get medical aid if symptoms persist.

Eye contact

In case of contact, immediately flush eyes with large quantities of water for at least 15 minutes until irritation subsides. Get medical attention immediately.

Symptoms: irritation

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Get medical attention immediately.

Immediate Medical Attention

Get medical attention immediately for inhalation (if continued difficulty), eye contact, and ingestion.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog

Specific hazards

No Information

Instructions

Use water spray to cool exposed surfaces.

Firefighter Protection

Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment as necessary. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations. Scrape up dried material and place into containers.

Environmental

No Information

Cleanup methods

Scrape up dried material and place into containers.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Avoid breathing vapor and contact with eyes, skin and clothing. Use only with adequate ventilation. Ensure fresh air entry during application and drying. Wash thoroughly after handling.

Storage

Avoid excessive heat and freezing.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Properties Status
---
Bulk Density
---
Lower Explosive Limit
N.E.
Odor
Slight
Flammability
Non-Flammable
Decomposition Temperature
Not Established
Cloud Point
---
Odor Threshold
Not Established
Softening Point
---
Dynamic Viscosity
Not Established
Upper Explosive Limit
N.E.
Form
---
Molecular Weight
---
Solubility In Water
Not Established
Solubility In Fat
---
Relative Density
---
Auto Ignition Temperature
Not Established
Crystallisation Point
---
Evaporation Rate
Slower Than n-Butyl Acetate
Freezing Point
Not Established
Ph
Not Applicable
Vapor Pressure
Not Established
Explosive Limits
---
Physical State
Paste
Solubility
---
Colour
Gray
Flash Point
Seta Closed Cup: 100 °C
Density
1.53 - 1.53 g/cm3
Vapor Density
Heavier Than Air
Physical State Data
liquid
Relative Evaporation Rate
---
Solidification Point
---
Partition Coefficient
Not Established
Colour Intensity
---
Metal Corrosion
---
Boiling Point
100 - 100 °C
Kinematic Viscosity
---
State Under Standard Conditions
---
Appearance
Gray
Melting Point
---
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Avoid

Excessive heat and freezing.

Incompatible

Incompatible with strong bases and oxidizing agents.

Decomposition

Normal decomposition products, i.e., COx, NOx.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AMP Concrete & Masonry Self-Leveling Sealant - Gray?

The signal word is no signal word.

What is the physical form of AMP Concrete & Masonry Self-Leveling Sealant - Gray?

AMP Concrete & Masonry Self-Leveling Sealant - Gray is a paste appearing as gray with gray color. It has slight odor.

What is AMP Concrete & Masonry Self-Leveling Sealant - Gray used for?

Caulking Compound

What are the hazard statements for AMP Concrete & Masonry Self-Leveling Sealant - Gray?

This substance has 1 hazard statement:

  • Not a hazardous substance or mixture.