NextSDS Logo
Safety Data Sheet EN

Concrete Floor Leveler Ready Made

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Concrete Floor Leveler Ready Made
Product Code
7972901

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Spackling Compound

Manufacturers & Suppliers

D

DAP Global Inc.

manufacturer

2400 Boston Street Suite 200, Baltimore, MD 21224-4723

888-327-8477

Emergency Contacts

Transportation

1-800-535-5053

Transportation

1-352-323-3500

Poison Control

1-800-222-1222

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4
Carc. Cat. 1A
STOT RE Cat. 1
STOT SE Cat. 1

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H332 Harmful if inhaled.
H350 May cause cancer.
H370 Causes damage to organs.
H372 Causes damage to organs through prolonged or repeated exposure.

Precautionary Statements

P201 Obtain special instructions before use.
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P264 Wash thoroughly after handling.
P270 Do no eat, drink or smoke when using this product.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P308 + P311 IF exposed or concerned: Call a POISON CENTER/doctor/...
P308 + P313 IF exposed or concerned: Get medical advice/attention.
P312 Call a POISON CENTER or doctor/physician if you feel unwell.
P321 Specific treatment (see ... on this label).
P405 Store locked up.
P501 Dispose of contents/container.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Quartz 14808-60-7 30 - 60% Yes
Limestone 1317-65-3 3 - 7% No
Clay 1332-58-7 3 - 7% No
Titanium dioxide 13463-67-7 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If you experience difficulty in breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.

Skin contact

Wash skin with soap and water for 15 minutes. Get medical aid if symptoms persist.

Eye contact

In case of contact, immediately flush eyes with large quantities of water for at least 15 minutes until irritation subsides. Get medical attention immediately.

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Get medical attention immediately.

Immediate Medical Attention

Get medical attention immediately if difficulty in breathing continues, if symptoms of skin contact persist, if eye contact occurs, or if swallowed.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Spray or Fog, Water

Instructions

Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear. Use water spray to cool exposed surfaces.

Firefighter Protection

Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

No Information

Cleanup methods

absorb with inert material and dispose of in accordance with applicable regulations

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

KEEP OUT OF REACH OF CHILDREN! DO NOT TAKE INTERNALLY. Use only with adequate ventilation. Ensure fresh air entry during application and drying. Do not breathe dust. Removal of this product after use will result in the generation of Dust. If dry-sanded, exposure to dust may result in the build-up of material in eyes, ears, nose, and mouth which may cause irritation. While dry sanding, use of a NIOSH-approved dust mask is recommended. Wash thoroughly after handling.

Storage

Avoid excessive heat and freezing. Do not store at temperatures above 120 °F (49 °C). Store away from caustics and oxidizers. Keep containers tightly closed.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
Between 7.0 and 12.0
Solidification Point
---
Relative Evaporation Rate
---
Physical State Data
liquid
Metal Corrosion
---
Kinematic Viscosity
---
State Under Standard Conditions
---
Flammability
Non-Flammable
Vapor Density
Heavier Than Air
Upper Explosive Limit
N.E.
Softening Point
---
Lower Explosive Limit
N.E.
Solubility In Fat
---
Evaporation Rate
Slower Than n-Butyl Acetate
Odor Threshold
Not Established
Freezing Point
Not Established
Properties Status
---
Partition Coefficient
Not Established
Auto Ignition Temperature
Not Established
Voc Content
---
Relative Density
---
Colour Intensity
---
Flash Point
100 °C, Seta Closed Cup
Explosive Limits
---
Vapor Pressure
Not Established
Decomposition Temperature
Not Established
Colour
---
Solubility In Water
Not Established
Bulk Density
---
Cloud Point
---
Density
1.84 - 1.84 g/cm3
Form
---
Appearance
Gray
Melting Point
---
Solubility
---
Dynamic Viscosity
Not Established
Crystallisation Point
---
Odor
Little or No
Physical State
Paste
Molecular Weight
---
Boiling Point
100 - 100 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Avoid

Do not breathe dust. Avoid dust formation in confined areas. Excessive heat and freezing.

Incompatible

Incompatible with strong bases and oxidizing agents.

Decomposition

Above 1450 degree C: SO2 and CaO.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Concrete Floor Leveler Ready Made?

The signal word is danger.

What is the physical form of Concrete Floor Leveler Ready Made?

Concrete Floor Leveler Ready Made is a paste appearing as gray . It has little or no odor.

What is Concrete Floor Leveler Ready Made used for?

Spackling Compound

What are the hazard statements for Concrete Floor Leveler Ready Made?

This substance has 4 hazard statements:

  • H332: Harmful if inhaled.
  • H350: May cause cancer.
  • H370: Causes damage to organs.
  • H372: Causes damage to organs through prolonged or repeated exposure.