Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Gorilla Super Glue Gel
- Product Form
- Mixture
- Synonyms
- Ethyl Cyanoacrylate Adhesive
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive for metal, wood, ceramics, leather, paper, most plastics and more
Manufacturers & Suppliers
The Gorilla Glue Company
manufacturer
2101 E. Kemper Road, Cincinnati, Ohio 45241
513-271-3300
http://www.gorillatough.com
Emergency Contacts
Emergency Contact
(800) 966-3458
During Business Hours
Emergency Contact
(800) 420-7186
Outside Business Hours
Prosar
1-800-420-7186
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethyl cyanoacrylate | 7085-85-0 | 86 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air and keep at rest in a position comfortable for breathing. If you feel unwell, seek medical advice.
Symptoms: May cause respiratory irritation.
Remove contaminated clothing. Gently wash with plenty of soap and water followed by rinsing with water for at least 15 minutes. Call a POISON CENTER or doctor/physician if you feel unwell. Wash contaminated clothing before reuse.
Symptoms: Causes skin irritation.
Rinse cautiously with water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Obtain medical attention.
Symptoms: Causes serious eye irritation.
Rinse mouth. Do not induce vomiting. Immediately call a POISON CENTER or doctor/physician.
Symptoms: Ingestion is likely to be harmful or have adverse effects.
Immediate Medical Attention
If medical advice is needed, have product container or label at hand.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical powder, alcohol-resistant foam, carbon dioxide (CO₂).
Do not use a heavy water stream. Use of heavy stream of water may spread fire.
Fire Hazard: Not flammable. Explosion Hazard: Product is not explosive. Reactivity: Rapid polymerization occurs upon contact with water or alkaline substances. As a result, heat is generated. Skin inflammation or burns may occur upon contact during this polymerization. May react with strong oxidizers, increasing risk of fire or explosion.
Exercise caution when fighting any chemical fire.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Upon arrival at the scene, a first responder is expected to recognize the presence of dangerous goods, protect oneself and the public, secure the area, and call for the assistance of trained personnel as soon as conditions permit.
Prevent entry to sewers and public waters.
Clean up spills immediately and dispose of waste safely. Use only non-sparking tools.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety procedures.
Store in a dry, cool and well-ventilated place. Keep container closed when not in use. Store away from heat and incompatible materials. Protect from moisture.
Wash hands and other exposed areas with mild soap and water before eating, drinking, or smoking and again when leaving work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended handling and storage conditions (see section 7).
Rapid polymerization occurs upon contact with water or alkaline substances. As a result, heat is generated. Skin inflammation or burns may occur upon contact during this polymerization. May react with strong oxidizers, increasing risk of fire or explosion.
Hazardous polymerization will not occur.
Direct sunlight. Extremely high or low temperatures.
Strong acids, strong bases, strong oxidizers. Water.
Carbon Oxides (CO and CO₂) and other irritating compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Gorilla Super Glue Gel known by?
Gorilla Super Glue Gel is also known as: Ethyl Cyanoacrylate Adhesive
What is the hazard signal word for Gorilla Super Glue Gel?
The signal word is warning.
What is the physical form of Gorilla Super Glue Gel?
Gorilla Super Glue Gel is a liquid appearing as white water / straw colored . It has sharp, irritating odor.
What is the solubility of Gorilla Super Glue Gel?
Immiscible in water.
What is Gorilla Super Glue Gel used for?
Adhesive for metal, wood, ceramics, leather, paper, most plastics and more
What are the hazard statements for Gorilla Super Glue Gel?
This substance has 4 hazard statements:
- H227: Combustible liquid.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
What is the melting point of Gorilla Super Glue Gel?
The melting point is Not available and the boiling point is >100 °C (212 °F).