Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE C-IC SC0592 ACID CLEANER
- Synonyms
- SC0592 Cleaner
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
None identified
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ferric sulfate | 10028-22-5 | 10 - 30% | Yes |
| Sulfuric acid | 7664-93-9 | 10 - 30% | Yes |
| Nitric acid | 7697-37-2 | 5 - 10% | Yes |
| Ammonium bifluoride | 1341-49-7 | 1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist. If breathing is difficult, give oxygen. Trained personnel should administer 2.5% calcium gluconate through a nebulizer for 20 minutes.
Remove contaminated clothing and footwear while rinsing the affected area with large amounts of running water for at least 15 minutes. GET IMMEDIATE MEDICAL ATTENTION. If iced solution of 0.13% aqueous Benzalkonium Chloride (Zephiran) or 2.5% calcium gluconate gel is available, rinsing may be limited to 5 minutes, with the soak solution or gel applied as soon as the rinsing is stopped. If using calcium gluconate gel, it should be continuously re-applied and massaged into the affected area until pain has been relieved for at least 30 minutes. If Benzalkonium Chloride (Zephiran) or calcium gluconate gel is not available, rinsing must continue until medical treatment is provided.
Immediately flush affected eye with large amounts of gently flowing water or 0.9% sterile saline solution for at least 15 minutes. Hold eyelid wide open. Get immediate medical attention. Eye flushing should continue during transportation to a doctor.
Get immediate medical attention. Do not induce vomiting. Attempt immediate administration of a fluoride binding substance: milk, chewable calcium carbonate tablets or 4-8 ounces (120-240 ml) of milk of magnesia or a liquid antacid. Avoid large amounts of liquid as it may induce vomiting. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get immediate medical attention.
Medical Treatment
Ocular exposure to corrosive fluoride compounds has been treated with isotonic sodium chloride or magnesium chloride. Dermal exposure to corrosive fluoride compounds has been treated with calcium gluconate or calcium carbonate gel applied topically to the affected areas to relieve pain at the site of exposure. Treatment of hypocalcemia associated with corrosive fluoride compounds exposure may be corrected by intravenous calcium gluconate or calcium chloride. Treatment of hypomagnesemia may be corrected by intravenous magnesium sulfate. If cyanosis is severe, intravenous injection of methylene blue, 1 mg/kg body weight, may be of value.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use media appropriate for surrounding material.
Not available.
May react with metals to form flammable hydrogen gas. This product is an aqueous mixture which will not burn.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Dike the spilled material, where this is possible. Block any potential routes to water systems.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE C-IC 110 ACID CLEANER
---
BONDERITE C-IC 4409 AERO ACID CLEANER
---
BONDERITE C-IC ALBRITE HVY AERO ACID CLEANER
---
BONDERITE C-IC 2599X ACID CLEANER known as PARCO CLEANER 2599X
---
BONDERITE C-AK EC-76 ALKALINE CLEANER
---
BONDERITE C-AK T51 ALKALINE CLEANER
---
BONDERITE C-AK PRECLEAN 2960 ALKALINE CLEANER
---
BONDERITE C-IC 921 RF ACID CLEANER known as P3 RIDOLINE 921 RF
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists of this product. Wash thoroughly after handling. Do not take internally. For industrial use only. Use caution when combining with water; DO NOT add water to acid, ALWAYS add acid to water while stirring to prevent release of heat, steam and fumes.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Supplier recommends that this product be stored with a vented bung.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
Will not occur.
Store away from incompatible materials.
Avoid contact with organic materials, oils, greases, and any oxidizable materials. This product may react with strong alkalies. Adding water to this product may cause localized overheating and splattering.
May liberate hydrogen fluoride. Upon decomposition, this product may yield oxides of nitrogen and ammonia, carbon dioxide, carbon monoxide and other low molecular weight hydrocarbons. Oxides of sulfur.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3264
- Shipping Name
- Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid, Sulfuric acid)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is BONDERITE C-IC SC0592 ACID CLEANER known by?
BONDERITE C-IC SC0592 ACID CLEANER is also known as: SC0592 Cleaner
What is the hazard signal word for BONDERITE C-IC SC0592 ACID CLEANER?
The signal word is danger.
What is the physical form of BONDERITE C-IC SC0592 ACID CLEANER?
BONDERITE C-IC SC0592 ACID CLEANER is a liquid with brown color. It has sour/acid odor.
What is the solubility of BONDERITE C-IC SC0592 ACID CLEANER?
Complete
What is BONDERITE C-IC SC0592 ACID CLEANER used for?
None identified
What are the hazard statements for BONDERITE C-IC SC0592 ACID CLEANER?
This substance has 4 hazard statements:
- H272: MAY INTENSIFY FIRE; OXIDIZER.
- H290: MAY BE CORROSIVE TO METALS.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H350: MAY CAUSE CANCER.
What is the melting point of BONDERITE C-IC SC0592 ACID CLEANER?
The melting point is Not available. and the boiling point is > 225 °F (> 107.2 °C).