Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE C-IC DW 511L ACID CLEANER
- Product Code
- 596105
- Synonyms
- DW 511L
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Special product
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention. Administer oxygen or artificial respiration as needed. Do not use mouth-to-mouth method if victim ingested or inhaled the substance.
Symptoms: Delayed effects possible after inhalation.
Remove contaminated clothing and footwear. Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention. Launder contaminated clothing before reuse. Discard any shoes or clothing items that cannot be decontaminated.
Immediately flush affected eye with large amounts of gently flowing water or 0.9% sterile saline solution for at least 15 minutes. Hold eyelid wide open. Get immediate medical attention. Eye flushing should continue during transportation to a doctor.
Get immediate medical attention. Do not induce vomiting. If individual is conscious, wash out mouth with water. Provide a glass of water to dilute the material in the stomach. Never give anything by mouth to a victim who is unconscious or is having convulsions.
Immediate Medical Attention
Get immediate medical attention for inhalation, eye contact, and ingestion.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use media appropriate for surrounding material.
Not available.
This product is an aqueous mixture which will not burn.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up. Do not allow product to enter sewer or waterways.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE C-IC 110 ACID CLEANER
---
BONDERITE C-IC 7310 ACID CLEANER
---
BONDERITE C-IC 2065IT ACID CLEANER
---
BONDERITE C-IC 7005 ACID CLEANER
---
BONDERITE C-IC 243N ACID CLEANER
---
BONDERITE C-IC SC0592 ACID CLEANER
---
BONDERITE C-IC 151-2 ACID CLEANER BU
---
BONDERITE C-IC 4409 AERO ACID CLEANER
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing mists or aerosols of this product. Use only with adequate ventilation. Launder work clothes frequently. Do not store or consume food, drink, or tobacco products in areas where they may become contaminated with this material. Do not take internally. For industrial use only. Use caution when combining with water; DO NOT add water to acid, ALWAYS add acid to water while stirring to prevent release of heat, steam and fumes.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.
Wash thoroughly after handling. Launder work clothes frequently. Do not store or consume food, drink, or tobacco products in areas where they may become contaminated with this material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials.
This product may react with strong reducing agents. Avoid contact with organic materials, oils, greases, and any oxidizable materials. Adding water to this product may cause localized overheating and splattering. This product may react with strong alkalies. Metals.
Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Irritating and toxic gases or fumes may be released during a fire. Chromium oxide. Oxides of phosphorus.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3264
- Shipping Name
- Corrosive liquid, acidic, inorganic, n.o.s. (Phosphoric acid, Chromic acid)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is BONDERITE C-IC DW 511L ACID CLEANER known by?
BONDERITE C-IC DW 511L ACID CLEANER is also known as: DW 511L
What is the hazard signal word for BONDERITE C-IC DW 511L ACID CLEANER?
The signal word is danger.
What is the physical form of BONDERITE C-IC DW 511L ACID CLEANER?
BONDERITE C-IC DW 511L ACID CLEANER is a liquid with dark orange color. It has sour/acid odor.
What is the solubility of BONDERITE C-IC DW 511L ACID CLEANER?
Complete
What is BONDERITE C-IC DW 511L ACID CLEANER used for?
Special product
What are the hazard statements for BONDERITE C-IC DW 511L ACID CLEANER?
This substance has 10 hazard statements:
- H290: MAY BE CORROSIVE TO METALS.
- H302: HARMFUL IF SWALLOWED.
- H311 + H331: TOXIC IN CONTACT WITH SKIN OR IF INHALED.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H340: MAY CAUSE GENETIC DEFECTS.
- H350: MAY CAUSE CANCER.
- H360: MAY DAMAGE FERTILITY OR THE UNBORN CHILD.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of BONDERITE C-IC DW 511L ACID CLEANER?
The melting point is Not determined and the boiling point is 225 °F (107.2 °C)None.