Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE CATALYST R 397
- Product Form
- Hardener
- Product Code
- 515262
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The data for this section has not been processed yet.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration.
Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and footwear.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use NFPA Class B fire extinguishers (Carbon dioxide, all purpose dry chemical or alcohol foam) designed to extinguish flammable liquid fires. Polymer foam is preferred for large fires.
Not available.
During emergency conditions, overexposure to decomposition products may cause a health hazard. Symptoms may not be immediately apparent. Obtain medical attention.
Firefighters should wear self-contained breathing apparatus. Water may be ineffective, but may be used to cool exposed containers to prevent pressure build-up and possible auto-ignition or explosion when exposed to extreme heat. If water is used, fog nozzles are preferable.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Do not allow product to enter sewer or waterways.
Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective equipment and clothing during clean-up. Dispose of contaminated material as waste according to Section 13.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Keep container closed.
For safe storage, store at or above 0 °C (32°F)
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Normally stable.
Not available.
Will not occur.
Avoid excessive heat (>46°C (>115°F)) and sources of ignition.
Water Amines. Strong bases. Alcohols. Copper alloys.
Smoke. Oxides of carbon. Oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (Hexane, 1,6-diisocyanato-, homopolymer)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUENCE CATALYST R 397?
The signal word is danger.
What is the physical form of AQUENCE CATALYST R 397?
AQUENCE CATALYST R 397 is a liquid with yellow color. It has mild odor.
What is the solubility of AQUENCE CATALYST R 397?
Not determined
What are the hazard statements for AQUENCE CATALYST R 397?
This substance has 5 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H332: HARMFUL IF INHALED.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
What is the melting point of AQUENCE CATALYST R 397?
The melting point is Not determined and the boiling point is 230 °C (446°F).