Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE PL 2522
- Product Code
- 854872
- Synonyms
- LAW-2522
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Water based adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Boric acid | 10043-35-3 | 0.1 - 1% | Yes |
| Corn starch | 9005-25-8 | 10 - 30% | Yes |
IDH number: 854872 Product name: AQUENCE PL 2522 known as LAW-2522
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear. In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up as much material as possible.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Keep container closed.
Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use. Store at or above 0 °C.
Wash thoroughly after handling.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Do not freeze. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials.
Strong oxidizing agents. Acids.
Oxides of carbon. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is AQUENCE PL 2522 known by?
AQUENCE PL 2522 is also known as: LAW-2522
What is the hazard signal word for AQUENCE PL 2522?
The signal word is warning.
What is the physical form of AQUENCE PL 2522?
AQUENCE PL 2522 is a liquid with tan color. It has characteristic odor.
What is the solubility of AQUENCE PL 2522?
Miscible
What is AQUENCE PL 2522 used for?
Water based adhesive
What are the hazard statements for AQUENCE PL 2522?
This substance has 1 hazard statement:
- H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.
What is the melting point of AQUENCE PL 2522?
The melting point is 0 °C (32°F) (Freezing point) and the boiling point is 100 °C (212°F).