NextSDS Logo
Safety Data Sheet EN

AQUENCE SEAL N5050

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AQUENCE SEAL N5050
Product Code
2843966

Regulatory Identifiers

CAS Number
N/A

Identified Uses

adhesive, water-based

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
Polyethylene glycol 25322-68-3 10 - 30% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. Move to fresh air. If symptoms persist, seek medical advice.

Skin contact

Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention. Remove contaminated clothing and shoes.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical attention immediately.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Seek medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Specific hazards

This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Keep unnecessary personnel away.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so. Do not allow material to contaminate ground water system. Do not allow product to enter sewer or waterways.

Cleanup methods

Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective equipment and clothing during clean-up. Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling.

Storage

Do not freeze. Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
liquid
Kinematic Viscosity
---
Metal Corrosion
---
Form
---
Solubility
---
Molecular Weight
---
Partition Coefficient
Not determined
Odor
Neutral
Solidification Point
---
Physical State
Liquid
Flash Point
> 100 °C (> 212°F) ASTM D 93-96 Flash point
Colour
Translucent
Boiling Point
> 100 °C (> 212°F) Boiling point
Softening Point
---
Freezing Point
---
Vapor Pressure
Not available.
Crystallisation Point
---
Voc Content
Not available.
Vapor Density
Heavier than air.
Explosive Limits
---
Density
---
Lower Explosive Limit
Not available.
Melting Point
Not available.
Flammability
Not applicable
Relative Evaporation Rate
---
Odor Threshold
Not available.
Decomposition Temperature
Not available.
Appearance
---
Dynamic Viscosity
25,000 - 27,000 cp
Solubility In Water
Miscible
Properties Status
---
Auto Ignition Temperature
Not available.
State Under Standard Conditions
---
Upper Explosive Limit
Not available.
Ph
5 - 7
Bulk Density
---
Cloud Point
---
Relative Density
1.01
Solubility In Fat
---
Colour Intensity
---
Evaporation Rate
Same as water.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Do not freeze.

Incompatible

Contact with water reactive materials (such as oleum) can cause exothermic reactions.

Decomposition

Oxides of carbon. Irritating organic vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AQUENCE SEAL N5050?

The signal word is no signal word.

What is the physical form of AQUENCE SEAL N5050?

AQUENCE SEAL N5050 is a liquid with translucent color. It has neutral odor.

What is AQUENCE SEAL N5050 used for?

adhesive, water-based

What is the melting point of AQUENCE SEAL N5050?

The melting point is Not available. and the boiling point is > 100 °C (> 212°F) Boiling point.