NextSDS Logo
Safety Data Sheet EN

LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G
Product Code
33388

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 4 H227
Eye Irrit. Cat. 2B H320
Repr. Cat. 1B H360

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H227 COMBUSTIBLE LIQUID
H320 CAUSES EYE IRRITATION
H360 MAY DAMAGE FERTILITY OR THE UNBORN CHILD

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P264 Wash affected area thoroughly after handling.
P280 Wear protective gloves, clothing, eye and face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 Store in a well-ventilated place.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Beta-Methoxyethyl Cyanoacrylate 27816-23-5 80 - 100% Yes
Bis(2-hydroxy-3-tert-butyl-5-methylphenyl)methane 119-47-1 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, seek medical advice. If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel.

Skin contact

Rinse with running water and soap. Do not pull bonded skin apart. It may be gently peeled apart using a blunt object such as a spoon, preferably after soaking in warm soapy water. If lips are accidentally stuck together apply warm water to the lips and encourage maximum wetting and pressure from saliva inside the mouth. Peel or roll lips apart. Do not try to pull the lips apart with direct opposing action. If symptoms develop and persist, get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical attention immediately. Do not force eye open. Medical advice should be sought in case solid particles of cyanoacrylate trapped behind the eyelid cause any abrasive damage.

Ingestion

Seek immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person. Ensure breathing passages are not obstructed. The product will polymerize rapidly and bond to the mouth making it almost impossible to swallow. Saliva will separate any solidified product in several hours. Prevent the patient from swallowing any separated mass.

Immediate Medical Attention

Seek immediate medical attention. Surgery is not necessary to separate accidentally bonded tissues. Experience has shown that bonded tissues are best treated by passive, non-surgical first aid.

Medical Treatment

If rapid curing has caused thermal burns they should be treated symptomatically after adhesive is removed.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Unsuitable media

Not available.

Specific hazards

Not available.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear. Keep unnecessary personnel away. In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Ensure adequate ventilation. Wear appropriate personal protective equipment. Do not use cloths for mopping up. Flood with water to complete polymerization and scrape off the floor.

Materials: water

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Use only with adequate ventilation. Keep container closed. See Section 8 of the SDS for Personal Protective Equipment. Avoid contact with fabric or paper goods. Contact with these materials may cause rapid polymerization which can generate smoke and strong irritating vapors, and cause thermal burns.

Storage

Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.

Hygiene

Wash thoroughly after handling. When using, do not eat, drink or smoke.

Fire prevention

Keep in a cool, well ventilated area away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate local exhaust ventilation to maintain worker exposure below exposure limits.

Hands

Use nitrile gloves and aprons as necessary to prevent contact. Do not use PVC, nylon or cotton.

Eyes

Wear safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists.

Respiratory

Use NIOSH approved respirator if there is potential to exceed exposure limit(s).

Skin/Body

Use chemical resistant, impermeable clothing including gloves and either an apron or body suit to prevent skin contact. The information provided on personal protective equipment is for guidance purposes only. A full risk assessment should be conducted prior to using this product to determine the appropriate personal protective equipment to suit local conditions. Personal protective equipment should conform to the relevant EN standard.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
---
Relative Evaporation Rate
---
Metal Corrosion
---
Odor Threshold
Not available.
Solubility
Polymerises in presence of water. Water
Boiling Point
> 149 °C (> 300.2 °F) None
Molecular Weight
---
Decomposition Temperature
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Lower Explosive Limit
Not available.
Density
---
Softening Point
---
Vapor Density
---
Form
---
Properties Status
---
Crystallisation Point
---
Solubility In Water
---
Upper Explosive Limit
Not available.
Kinematic Viscosity
> 20.5 mm2/s
Freezing Point
---
Colour Intensity
---
Cloud Point
---
Voc Content
< 2 %; < 20 g/l (California SCAQMD Method 316B) (Estimated)
Flammability
The product is not flammable.
Evaporation Rate
Not available.
Vapor Pressure
< 0.2 mm hg None < 30.0000000 Pa None < 700 mbar (50 °C (122°F)) no method / method unknown < 0.3 mbar None
Dynamic Viscosity
900.0 - 1,500.0 mPa.s
Physical State
Liquid
Relative Density
1.1 at 23.9 °C (75.02 °F)
Solubility In Fat
---
Bulk Density
---
Melting Point
Not applicable, Product is a liquid
Partition Coefficient
Not available.
Colour
Colourless / Colorless to yellow
Flash Point
80 - 93.3 °C (176°F - 199.94 °F)
Solidification Point
---
Physical State Data
liquid
Odor
Odourless / Odorless
State Under Standard Conditions
---
Ph
Not applicable, Product reacts with water.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Not available.

Hazardous reactions

Rapid exothermic polymerization will occur in the presence of water, amines, alkalis and alcohols.

Avoid

Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight. Store away from incompatible materials.

Incompatible

Water. Alcohols. Amines. Bases.

Decomposition

None if used for intended purpose.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
NA 1993
Shipping Name
Combustible liquid, n.o.s. (Cyanoacrylate ester)
Transport Class
Combustible Liquid
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G?

The signal word is danger.

What is the physical form of LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G?

LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G is a liquid with colourless / colorless to yellow color. It has odourless / odorless odor.

What is the solubility of LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G?

Polymerises in presence of water. Water

What is LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G used for?

Adhesive

What are the hazard statements for LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G?

This substance has 3 hazard statements:

  • H227: COMBUSTIBLE LIQUID
  • H320: CAUSES EYE IRRITATION
  • H360: MAY DAMAGE FERTILITY OR THE UNBORN CHILD

What is the melting point of LOCTITE 403 LOW ODOR/BLOOM known as 403 PRISM 20 G?

The melting point is Not applicable, Product is a liquid and the boiling point is > 149 °C (> 300.2 °F) None.