Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Additive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrogen peroxide solution | 7722-84-1 | 30 - 60% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.
Remove contaminated clothing and footwear. Flush with large amounts of water. Seek immediate medical attention.
Rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
Get immediate medical attention. Do not induce vomiting.
Immediate Medical Attention
Seek immediate medical attention if symptoms develop or persist (inhalation). Seek immediate medical attention (skin, eye, ingestion).
Medical Treatment
If the product is ingested, probable mucosal damage may contraindicate the use of gastric lavage. Treat the affected person appropriately. A nasogastric or orogastric tube may be required for the reduction of severe distension due to gas formation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray or fog.
Not available.
This product is an oxidizing agent and is a serious fire and explosion risk. Do not permit contact with combustible, organic, or other oxidizable materials.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Do not allow product to enter sewer or waterways.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE M-AD 96 AUTODEPOSITION ADDITIVE known as AQUENCE 96 REGENERANT
---
BONDERITE M-PP 866 R AUTODEPOSITION PAINT known as AQUENCE 866 REPLENISHER
---
BONDERITE M-AD 1 PRETREATMENT ADDITIVE known as ADDITIVE 1
---
BONDERITE M-AD 4977B PRETREATMENT ADDITIVE known as ADDITIVE 4977B
---
BONDERITE C-IC ALDOX V AERO ACID DEOXIDIZER
---
BONDERITE C-IC 20 ACID DEOXIDIZER known as DEOXIDINE 20
---
BONDERITE C-IC WO 1 AERO ACID DEOXIDIZER
---
BONDERITE M-AD 426 PRETREATMENT ADDITIVE known as BONDERITE M-AD 426
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid contamination which can cause rapid decomposition, generating large quantities of oxygen. Keep away from heat, spark and flame. For industrial use only. Clothing or other material wet with this product and allowed to dry may become flammable. Do not return unused product to original container. Do not drop or drag containers; material is shock sensitive.
Store in a cool, dry, well-ventilated area. Remove all sources of ignition. Do not store around flammable or combustible materials. Keep in a container fitted with a vent / safety vent.
Wash thoroughly after handling.
Keep away from heat, spark and flame. Remove all sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Instability caused by elevated temperatures. Product may decompose over time.
This product may react with strong alkalies.
None under normal processing.
Heat, flames, sparks and other sources of ignition.
Strong acids and strong bases. Combustible materials.
Product may decompose and release oxygen, steam, peroxide vapor and heat.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2014
- Shipping Name
- Hydrogen peroxide, aqueous solution
- Transport Class
- 5.1 (8)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER?
The signal word is danger.
What is the physical form of BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER?
BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER is a liquid with colourless / colorless color. It has slight odor.
What is the solubility of BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER?
Complete
What is BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER used for?
Additive
What are the hazard statements for BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER?
This substance has 4 hazard statements:
- H272: MAY INTENSIFY FIRE; OXIDIZER.
- H302: HARMFUL IF SWALLOWED.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
What is the melting point of BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER?
The melting point is -33 °C (-27.4 °F) Approximately and the boiling point is > 106.1 °C (> 223°F).