Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER
- Product Code
- 1164791
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Auxiliary product
Uses advised against
None identified
Manufacturers & Suppliers
Henkel
manufacturer
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
hydrogen peroxide solution 30 - 60 %
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrogen peroxide solution | 7722-84-1 | 30 - 60% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.
Remove contaminated clothing and footwear. Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
Get immediate medical attention. Do not induce vomiting. Never give anything by mouth to a victim who is unconscious or is having convulsions.
Immediate Medical Attention
Get immediate medical attention. Treat the affected person appropriately.
Medical Treatment
A nasogastric or orogastric tube may be required for the reduction of severe distension due to gas formation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
This product is an oxidizing agent and is a serious fire and explosion risk. Do not permit contact with combustible, organic, or other oxidizable materials.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER
---
BONDERITE M-AD 24 AUTODEPOSITION ADDITIVE known as AQUENCE 24 OXIDIZER
---
BONDERITE C-IC HX-357 MU ACID DEOXIDIZER
---
BONDERITE M-AD 405
---
BONDERITE M-AD 76 AUTODEPOSITION ADDITIVE known as AQUENCE 76 REGENERANT
---
BONDERITE C-IC 151 ACID DEOXIDIZER
---
BONDERITE C-IC 2310 AERO ACID DEOXIDIZER
---
BONDERITE C-IC HX-357-2 MU ACID DEOXIDIZER PA18KG
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing mists or aerosols of this product. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.
Wash thoroughly after handling.
Remove all sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials.
This product may react with strong acids, bases and oxidizing agents.
Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2014
- Shipping Name
- Hydrogen peroxide, aqueous solution
- Transport Class
- 5.1 (8)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER?
The signal word is danger.
What is the physical form of BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER?
BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER is a liquid with colorless / colorless color. It has slight odor.
What is the solubility of BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER?
Complete Water
What is BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER used for?
Auxiliary product
What are the hazard statements for BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER?
This substance has 4 hazard statements:
- H272: MAY INTENSIFY FIRE; OXIDIZER.
- H302: HARMFUL IF SWALLOWED.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
What is the melting point of BONDERITE M-AD 140 known as AQUENCE 140 OXIDIZER?
The melting point is -26 °C (-14.8 °F) calculated and the boiling point is 106 °C (222.8 °F) calculated.