NextSDS Logo
Safety Data Sheet EN

TECHNOMELT

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT
Product Code
2818209

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Resp. Sens. Cat. 1
Skin Sens. Cat. 1
STOT RE Cat. 1

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H334 MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
H372 CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.

Precautionary Statements

P260 Do not breathe dust or fumes.
P264 Wash affected area thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, eye protection, and face protection.
P285 In case of inadequate ventilation wear respiratory protection.
P304 + P341 IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P342 + P311 If experiencing respiratory symptoms: Call a poison center or physician.
P352 IF ON SKIN: Wash with plenty of water.
P362 Take off contaminated clothing.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Isocyanate terminated polyurethane resin --- 60 - 80% Yes
Methylenebis(phenylisocyanate) 101-68-8 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.

Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours. Extreme asthmatic reactions can be life threatening.

Skin contact

Remove contaminated clothing and shoes. Rinse with running water and soap. Seek medical attention immediately. Wash contaminated clothing before reuse. Thoroughly clean shoes before reuse.

Symptoms: Known skin sensitizer.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical attention immediately.

Symptoms: Corneal injury, corneal burns, reversible corneal epithelial edema impairing vision.

Ingestion

If material is ingested, immediately contact a physician or poison control center. Keep individual calm. DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Seek medical attention immediately.

Immediate Medical Attention

Seek medical attention immediately.

Medical Treatment

Stain for evidence of corneal injury. If cornea is burned, instill antibiotic steroid preparation frequently. Treat symptomatically as for contact dermatitis or thermal burns. Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Specific hazards

At higher temperatures isocyanate may be released. The product may undergo spontaneous polymerization at high temperatures. Polymerization is exothermic and may cause damage to the container and/or release of thermal decomposition products. Sealed containers at elevated temperatures or contaminated with water may rupture explosively.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.

Small spill

For minor spills, absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution; mixture of 80% water and 20% non-ionic surfactant Tergitol TMN-10; or 90% water, 3-8% concentrated ammonia and 2% detergent. Allow to stand uncovered for 48 hours to let carbon dioxide escape.

Large spill

Large quantities may be pumped into closed, but not sealed containers for disposal. If temporary control of isocyanate vapor is required, a blanket of protein foam (available at most fire departments) may be placed over spill.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.

Materials: sawdust or other absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Wear suitable protective clothing, safety glasses and gloves. See Section 8 of the SDS for Personal Protective Equipment. Keep container closed.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Protect from direct sunlight.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Voc Content
Not available.
Vapor Density
Not available.
Dynamic Viscosity
30,000 - 52,000 mPa.s
Vapor Pressure
Not available.
Form
---
Odor Threshold
Not available.
Lower Explosive Limit
Not available.
Odor
Typical
Upper Explosive Limit
Not available.
Flash Point
Product is a solid.
Decomposition Temperature
Not available.
Flammability
Not applicable
Density
---
Colour
Beige
Melting Point
Not available.
Physical State
Solid
Freezing Point
---
Physical State Data
liquid
Crystallisation Point
---
Solubility In Water
Not available.
Kinematic Viscosity
---
Molecular Weight
---
Bulk Density
---
Relative Evaporation Rate
---
State Under Standard Conditions
---
Explosive Limits
---
Partition Coefficient
Not available.
Solubility In Fat
---
Colour Intensity
---
Metal Corrosion
---
Cloud Point
---
Solubility
---
Softening Point
---
Appearance
---
Auto Ignition Temperature
Not available.
Relative Density
1.06 at 20 °C (68°F)
Properties Status
---
Boiling Point
Not available.
Ph
Not applicable
Evaporation Rate
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Exothermic. Polymerization may occur at elevated temperature or in the presence of incompatible materials.

Avoid

Avoid moisture. Container can be pressurised by carbon dioxide due to reaction with humid air and/or water. Extremes of temperature and direct sunlight. Contamination with water. Keep away from heat, ignition sources and incompatible materials.

Incompatible

Water. Alcohols. Amines. Moisture. Strong acids and strong bases.

Decomposition

Upon decomposition, this product may yield gaseous nitrogen oxides, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Hydrogen cyanide. Isocyanate vapors

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT?

The signal word is danger.

What is the physical form of TECHNOMELT?

TECHNOMELT is a solid with beige color. It has typical odor.

What is TECHNOMELT used for?

Adhesive

What are the hazard statements for TECHNOMELT?

This substance has 5 hazard statements:

  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
  • H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.

What is the melting point of TECHNOMELT?

The melting point is Not available. and the boiling point is Not available..