Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B
- Product Code
- 1219068
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
2-Component polyurethane adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methylenebis(phenylisocyanate) | 101-68-8 | 60 - 100% | No |
| Glyceridic oil | --- | 10 - 30% | No |
| Methylene bisphenyl isocyanate | 26447-40-5 | 0.1 - 1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. For severe exposures, get under safety shower after removing clothing. Wash clothing before reuse.
Symptoms: Irritation.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Symptoms: Workplace vapors have produced reversible corneal epithelial edema impairing vision.
Do not induce vomiting. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get medical attention.
Medical Treatment
Eyes: Stain for evidence of corneal injury. If cornea is burned, instill antibiotic steroid preparation frequently. Skin: Treat symptomatically as for contact dermatitis or thermal burns. Respiratory: Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry chemical or carbon dioxide.
Water or fog may cause frothing which can be violent especially if sprayed into containers of hot or burning liquid.
MDI vapors and other irritating, highly toxic gases may be generated by thermal decomposition or combustion. At temperatures above 204.4°C (400°F), polymeric MDI can polymerize and decompose which can cause pressure build-up in closed containers. Explosive rupture is possible. The product may undergo spontaneous polymerization at high temperatures. Polymerization is exothermic and may cause damage to the container and/or release of thermal decomposition products. Sealed containers at elevated temperatures or contaminated with water may rupture explosively.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel. Remove all sources of ignition. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.
For minor spills, absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution: mixture of 80% water and 20% non-ionic surfactant Tergitol TMN-10; or 90% water, 3-8% concentrated ammonia and 2% detergent. Add about ten parts of neutralizer per part of isocyanate, with mixing. Allow to stand uncovered for 48 hours to let carbon dioxide escape.
Large quantities may be pumped into closed, but not sealed containers for disposal.
Do not allow product to enter sewer or waterways.
absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution
Materials: sawdust or other absorbent
Related Products
Similar products with comparable safety profiles
LOCTITE UR S117 known as MACROPLAST SIA-117
---
LOCTITE HD 8340RD known as MACROPLAST UR-8340RD
---
LOCTITE UK 3182 B 2-PART POTTING URETHANE
---
LOCTITE EA 3116 known as Macroplast EP3116 20L EDFN
---
LOCTITE UK 5400
---
LOCTITE UR 3370 WH known as LOCTITE® 3370™ POLYURETHANE A
---
LOCTITE 3090 Part B
---
LOCTITE DURO-TAK UV 7020 ULTRA DR-F181KG
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Exposure to vapors of heated MDI can be extremely dangerous. Use only with adequate ventilation. Protect from moisture. Keep container closed. Employee education and training in the safe use and handling of this compound are required under the OSHA Hazard Communication Standard.
Store between 16 °C (60.8 °F) and 37 °C (98.6 °F). Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store away from heat, sparks, flames, or other sources of ignition. Store original or opened drums absolutely dry and always close it air-tight.
Wash thoroughly after handling.
Store away from heat, sparks, flames, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Contact with moisture, other materials that react with isocyanates, or temperatures above 350°F (177°C), may cause polymerization. Uncontrolled polymerization may cause rapid evolution of heat and increase in pressure that could result in violent rupture of sealed storage vessels or containers.
Avoid moisture. Container can be pressurised by carbon dioxide due to reaction with humid air and/or water. Prolonged heating at temperatures above 150°C. Protect from direct sunlight. Freezing conditions. Keep away from heat, ignition sources and incompatible materials. Contamination with water.
Amines. Alcohols. Acids. Bases. Reaction with water, formation of CO2
Oxides of carbon. Hydrogen cyanide. Oxides of nitrogen. Irritating organic vapours. Isocyanate vapors
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- RQ, Environmentally hazardous substance, liquid, n.o.s.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B?
The signal word is danger.
What is the physical form of LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B?
LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B is a liquid with brown color. It has negligible odor.
What is LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B used for?
2-Component polyurethane adhesive
What are the hazard statements for LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B?
This substance has 6 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H332: HARMFUL IF INHALED.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE UK 180 B 2-PART POLYURETHANE, PART B known as MACROPLAST UK 180B?