01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001
Product Code
OM0682C8

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Hotmelt adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.

Skin contact

Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

Ingestion of solid adhesive is not expected to be hazardous. If symptoms develop and persist, get medical attention.

Immediate Medical Attention

Seek immediate medical attention for skin contact. Seek medical attention for eye contact and if symptoms persist for inhalation or ingestion.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.

Unsuitable media

Not available.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow material to contaminate ground water system.

Cleanup methods

Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.

Storage

Keep cool in accordance with information on label and in Technical Data Sheets.

Hygiene

Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use adequate ventilation to remove molten vapors or fumes.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.

Respiratory

Solid Resin: Dust safety masks are recommended when the potential for dust inhalation exists. Molten Resin: Use a NIOSH approved air-purifying respirator with an organic vapor cartridge.

Skin/Body

Insulated gloves and long sleeved clothing are strongly recommended when working with molten adhesive.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Amber
Colour Intensity
---
Form
---
Odor
Odourless / Odorless
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
137.7 °C (279.9 °F) (Softening Point)
Boiling Point
>280.0 °C (>536°F)
Flash Point
>280.00 °C (>536°F); Estimated
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not determined
Vapor Density
---
Relative Density
0.98
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Insoluble Tap water
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
0.00 %
Metal Corrosion
---
Dynamic Viscosity
3,800 - 5,500 cp
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Excessive heat.

Incompatible

Acids. Bases. Oxidizing agents.

Decomposition

Carbon dioxide, carbon monoxide and irritating and/or toxic gases and particulate may be generated by thermal decomposition or combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001?

The signal word is no signal word.

What is the physical form of TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001?

TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001 is a solid with amber color. It has odourless / odorless odor.

What is the solubility of TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001?

Insoluble Tap water

What is TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001 used for?

Hotmelt adhesive

What are the hazard statements for TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001?

This substance has 3 hazard statements:

  • MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS.
  • STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
  • VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION.

What is the melting point of TECHNOMELT PA 682 known as MACROMELT 682 VZHHD001?

The melting point is 137.7 °C (279.9 °F) (Softening Point) and the boiling point is >280.0 °C (>536°F).