NextSDS Logo
Safety Data Sheet EN

LOCTITE FLAMECONTROL 6060A WH 5

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE FLAMECONTROL 6060A WH 5
Product Code
3088315

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Paint and coatings

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2A H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 CAUSES SERIOUS EYE IRRITATION.

Precautionary Statements

P264 Wash affected area thoroughly after handling.
P280 Wear eye and face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Titanium dioxide < 1% particles with diameter ≤ 10 μm 13463-67-7 10 - 30% Yes
Pentaerythritol 115-77-5 5 - 10% Yes
Melamine 108-78-1 5 - 10% Yes
Urea 57-13-6 1 - 5% Yes
2-Butoxyethanol 111-76-2 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms develop and persist, get medical attention.

Skin contact

Wash affected area immediately with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

If material is ingested, immediately contact a physician or poison control center. DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

If material is ingested, immediately contact a physician or poison control center.

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Unsuitable media

Not available.

Specific hazards

This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

Keep unnecessary personnel away.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Small spill

Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers.

Large spill

For large spills dike ahead and collect liquid.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers. For large spills dike ahead and collect liquid.

Materials: vermiculite, clay or other suitable non-biodegradable absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash thoroughly after handling. Use only with adequate ventilation. Avoid contact with eyes, skin and clothing. Do not taste or swallow. Keep container closed. Do not breathe gas/fumes/vapor/spray.

Storage

Keep the container tightly closed and in a cool, well-ventilated place. Protect from freezing.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
White
Colour Intensity
---
Form
---
Odor
Ammoniacal
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
< 5 °C (< 41°F) (Freezing point)
Boiling Point
100 °C (212°F)
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined
Vapor Pressure
Not determined
Vapor Density
---
Relative Density
1.45 at 20 °C (68°F)
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not available.
Solubility
Soluble Water
Partition Coefficient
Not determined
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
27.8 g/l
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Freezing conditions.

Incompatible

Avoid contact with materials that are water reactive.

Decomposition

Oxides of carbon. Thermal decomposition can lead to release of irritating gases and vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE FLAMECONTROL 6060A WH 5?

The signal word is warning.

What is the physical form of LOCTITE FLAMECONTROL 6060A WH 5?

LOCTITE FLAMECONTROL 6060A WH 5 is a liquid with white color. It has ammoniacal odor.

What is the solubility of LOCTITE FLAMECONTROL 6060A WH 5?

Soluble Water

What is LOCTITE FLAMECONTROL 6060A WH 5 used for?

Paint and coatings

What are the hazard statements for LOCTITE FLAMECONTROL 6060A WH 5?

This substance has 1 hazard statement:

  • H319: CAUSES SERIOUS EYE IRRITATION.

What is the melting point of LOCTITE FLAMECONTROL 6060A WH 5?

The melting point is < 5 °C (< 41°F) (Freezing point) and the boiling point is 100 °C (212°F).