NextSDS Logo
Safety Data Sheet EN

AQUENCE EPIX BC 5000

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AQUENCE EPIX BC 5000
Product Form
Coating
Product Code
2678727

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

CHEMTREC

1-703-527-3887

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

| Hazardous Component(s) | CAS Number | Weight %* | | Polypropylene glycol | 25322-69-4 | 1 - 5 |

Chemical Name CAS Number Concentration Hazardous
Polypropylene glycol 25322-69-4 1 - 5% Yes

IDH number: 2678727 Product name: AQUENCE EPIX BC 5000

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.

Skin contact

Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention.

Eye contact

In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.

Ingestion

Get immediate medical attention. Do not induce vomiting.

Immediate Medical Attention

Get immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Unsuitable media

Not available.

Specific hazards

This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Keep unnecessary personnel away.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so. Do not allow material to contaminate ground water system. Do not allow product to enter sewer or waterways.

Cleanup methods

Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective equipment and clothing during clean-up. Refer to Section 8 "Exposure Controls / Personal Protection" prior to clean up. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling.

Storage

Do not freeze. Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Beige
Colour Intensity
---
Form
---
Odor
Acrylic
Odor Threshold
Not available.
Ph
8.0 - 9.0
Melting Point
Not applicable, Product is a liquid
Boiling Point
100 °C (212°F)no method / method unknown Dispersion, water based
Flash Point
Aqueous solution
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Same as water.
Vapor Pressure
23.4 hPa (20 °C (68°F))
Vapor Density
---
Relative Density
0.9 - 1.1 at 23 °C (73.4 °F)
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
fully miscible
Partition Coefficient
Not determined
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
Not available.
Metal Corrosion
---
Dynamic Viscosity
300 - 700 mPa.s
Kinematic Viscosity
450 - 550 mm2/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Do not freeze.

Incompatible

Contact with water reactive materials (such as oleum) can cause exothermic reactions.

Decomposition

Oxides of carbon. Irritating organic vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AQUENCE EPIX BC 5000?

The signal word is no signal word.

What is the physical form of AQUENCE EPIX BC 5000?

AQUENCE EPIX BC 5000 is a liquid with beige color. It has acrylic odor.

What is the solubility of AQUENCE EPIX BC 5000?

fully miscible

What is the melting point of AQUENCE EPIX BC 5000?

The melting point is Not applicable, Product is a liquid and the boiling point is 100 °C (212°F)no method / method unknown Dispersion, water based.