NextSDS Logo
Safety Data Sheet EN

AQUENCE EPIX BC 900F DR

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AQUENCE EPIX BC 900F DR
Product Code
2460090

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coating

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. Move to fresh air. Immediately remove victim to fresh air.

Skin contact

Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and shoes. Rinse with running water and soap.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Flush eyes with plenty of water for at least 5 minutes.

Ingestion

Never give anything by mouth to an unconscious person.

Immediate Medical Attention

If symptoms persist, seek medical advice. Get immediate medical attention. Seek medical attention immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

carbon dioxide, foam, powder, water spray jet, fine water spray

Specific hazards

This product is an aqueous mixture which will not burn. If evaporated to dryness, the solid residue may pose a slight fire hazard. In case of fire toxic gases can be released.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Keep unnecessary personnel away. Wear respiratory protection equipment according to ambient air conditions.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear respiratory protection equipment according to ambient air conditions.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so. Do not allow material to contaminate ground water system. Do not allow product to enter sewer or waterways. Do not empty into drains / surface water / ground water / soil.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Remove with liquid-absorbing material (sand, peat, sawdust).

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust), liquid-absorbing material (sand, peat, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid skin and eye contact.

Storage

Do not freeze. Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store in sealed original container. Store in a dry place.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use local ventilation if general ventilation is insufficient to maintain vapor concentration below established exposure limits. Ensure good ventilation/extraction.

Hands

Use impermeable gloves and protective clothing as necessary to prevent skin contact. Use of Butyl or Nitrile Rubber gloves is recommended.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Safety showers and eye wash stations should be available. Wear protective glasses.

Respiratory

Use NIOSH approved respirator if there is potential to exceed exposure limit(s). Suitable breathing mask when there is inadequate ventilation.

Skin/Body

Use impermeable gloves and protective clothing as necessary to prevent skin contact. Wear protective equipment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
light beige
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
Not available.
Ph
7.5 - 9.0
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
> 93 °C (> 199.4 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Same as water.
Vapor Pressure
Not available.
Vapor Density
Heavier than air.
Relative Density
---
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not determined
Solubility In Water
Not available.
Solubility In Fat
---
Molecular Weight
---
Voc Content
Not available.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur. None under normal processing.

Avoid

Do not freeze. None if used for intended purpose.

Incompatible

Contact with water reactive materials (such as oleum) can cause exothermic reactions. None if used for intended purpose.

Decomposition

Oxides of carbon. Irritating organic vapours. No decomposition if used according to specifications.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AQUENCE EPIX BC 900F DR?

The signal word is no signal word.

What is the physical form of AQUENCE EPIX BC 900F DR?

AQUENCE EPIX BC 900F DR is a liquid with light beige color. It has characteristic odor.

What is AQUENCE EPIX BC 900F DR used for?

Coating

What is the melting point of AQUENCE EPIX BC 900F DR?

The melting point is Not available. and the boiling point is Not available..