Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg
- Product Code
- 3047284
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Polyamide
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Carbon black | 1333-86-4 | 0.1 - 1% | Yes |
IDH number: 3047284 Product name: TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.
Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.
Symptoms: Molten adhesive may cause severe burns.
If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.
Ingestion of solid adhesive is not expected to be hazardous. If symptoms develop and persist, get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.
Not available.
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.
Firefighter Protection
Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
No special environmental precautions required. Do not allow material to contaminate ground water system.
Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.
Related Products
Similar products with comparable safety profiles
TECHNOMELT PA 2391 known as MACROMELT 2391 40LB
---
TECHNOMELT PA 2192 known as MACROMELT 2192 18.14 KG.
---
TECHNOMELT PA 652 N known as MACROMELT OM 652 KG20
---
TECHNOMELT PA 6301 known as MACROMELT 6301 40LB EN
---
TECHNOMELT MELTACE 709-4 20KG
---
TECHNOMELT PA 2192B known as MACROMELT 2192 B
---
TECHNOMELT PUR 5319 TSE-SL 2KG
---
TECHNOMELT PUR 6348 SL 2KG
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.
Store in a dry place.
Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Not available.
Will not occur.
To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).
Oxidizing agents.
Thermal decomposition can lead to release of irritating gases and vapors. carbon monoxide carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg?
The signal word is no signal word.
What is the physical form of TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg?
TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg is a solid with black color. It has resinous odor.
What is the solubility of TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg?
Insoluble Water
What is TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg used for?
Polyamide
What are the hazard statements for TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg?
This substance has 1 hazard statement:
- MOLTEN ADHESIVE MAY CAUSE SEVERE BURNS. VAPORS ABOVE MOLTEN ADHESIVE MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION. STATIC CHARGES GENERATED BY EMPTYING PACKAGE IN OR NEAR FLAMMABLE VAPORS MAY CAUSE IGNITION.
What is the melting point of TECHNOMELT PA 2302 BLACK known as MACROMELT 2302 S 20kg?
The melting point is 200 - 210 °C (392°F - 410°F) and the boiling point is > 220 °C (> 428°F).