Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR
- Product Code
- 1108508
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Urea | 57-13-6 | 5 - 10% | No |
| Ammonium hydroxide | 1336-21-6 | 1 - 5% | No |
| 3- Aminomethyl-3,5,5-trimethylcyclohexylamine | 2855-13-2 | 0.1 - 1% | No |
IDH number: 1108508 Product name: AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, seek medical advice. If not breathing, give artificial respiration.
Immediately wash skin thoroughly with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get immediate medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Get immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use media appropriate for surrounding material.
None identified.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers.
For large spills dike ahead and collect liquid.
Prevent further leakage or spillage if safe to do so. Do not allow product to enter sewer or waterways.
Keep unnecessary personnel away. Ensure adequate ventilation. Wear appropriate protective equipment and clothing during clean-up. Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers. For large spills dike ahead and collect liquid.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear suitable protective clothing, safety glasses and gloves. Avoid skin and eye contact. Wash hands before breaks and immediately after handling the product. Avoid breathing vapors or mists of this product. Keep container closed.
Protect from freezing.
Wash hands before breaks and immediately after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Not available.
Will not occur.
Store away from incompatible materials. Freezing conditions.
This product may react with strong acids, bases and oxidizing agents.
Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR?
The signal word is warning.
What is the physical form of AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR?
AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR is a liquid with opaque white color. It has ammoniacal odor.
What is AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR used for?
Adhesive
What are the hazard statements for AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR?
This substance has 3 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of AQUENCE LG 30MCR KNOWN AS OPTAL LG 30MCR?
The melting point is 0.0 °C (32°F) and the boiling point is 100 °C (212°F).