Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUENCE LG 30 KNOWN AS OPTAL LG 30
- Product Code
- 514968
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Urea | 57-13-6 | 10 - 20% | Yes |
| Ammonium hydroxide | 1336-21-6 | 1 - 5% | Yes |
IDH number: 514968 Product name: AQUENCE LG 30 KNOWN AS OPTAL LG 30
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is difficult, give oxygen. If symptoms develop and persist, get medical attention.
Wash affected area immediately with soap and water. Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If symptoms develop and persist, get medical attention.
If material is ingested, immediately contact a physician or poison control center. DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
If symptoms develop and persist, get medical attention. If material is ingested, immediately contact a physician or poison control center.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.
This product is an aqueous mixture which will not burn. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Keep unnecessary personnel away. Fire fighters should avoid inhaling any combustion products.
Firefighter Protection
Fire fighters should wear full-face, self contained breathing apparatus and impervious protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Keep unnecessary personnel away.
Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers.
For large spills dike ahead and collect liquid.
Prevent further leakage or spillage if safe to do so. Prevent contamination of soil and water.
Small spills can be absorbed with vermiculite, clay or other suitable non-biodegradable absorbent material, scooped up and placed in containers. For large spills dike ahead and collect liquid.
Materials: vermiculite, clay or other suitable non-biodegradable absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash thoroughly after handling. Use only with adequate ventilation. Avoid contact with eyes, skin and clothing. Do not taste or swallow. Keep container closed. Do not breathe gas/fumes/vapor/spray.
Keep container closed. Protect from freezing.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
Will not occur.
Store away from incompatible materials.
Keep away from strong oxidizing agents, strong Lewis or mineral acids.
Oxides of carbon. Oxides of nitrogen. Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUENCE LG 30 KNOWN AS OPTAL LG 30?
The signal word is warning.
What is the physical form of AQUENCE LG 30 KNOWN AS OPTAL LG 30?
AQUENCE LG 30 KNOWN AS OPTAL LG 30 is a liquid with white color. It has ammoniacal odor.
What are the hazard statements for AQUENCE LG 30 KNOWN AS OPTAL LG 30?
This substance has 2 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of AQUENCE LG 30 KNOWN AS OPTAL LG 30?
The melting point is < 0.0 °C (< 32°F) and the boiling point is > 100.0 °C (> 212°F).