Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON
- Synonyms
- VO-2CA
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Corrosion Protection Oils
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
CHEMTREC
1-703-527-3887
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Petroleum Distillates | --- | 80 - 100% | Yes |
| Diethylene glycol monobutyl ether | 112-34-5 | 1 - 5% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.
Flush with large amounts of water. If skin irritation persists, call a physician.
Rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Give one to two glasses of water or milk. Never give anything by mouth to a victim who is unconscious or is having convulsions.
Immediate Medical Attention
This material, if aspirated into the lungs, may cause lipoid pneumonitis. Treat affected person appropriately.
Medical Treatment
Treat affected person appropriately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
This product is combustible at high temperatures.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Dike the spilled material, where this is possible. Ventilate area. Do not allow product to enter sewer or waterways.
Collect spilled material with an inert absorbent such as sand or vermiculite. Place in properly labeled closed container. Dispose of according to Federal, State and local governmental regulations.
Materials: inert absorbent such as sand or vermiculite
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Provide adequate ventilation. Avoid breathing vapors or mists of this product. Wash thoroughly after handling.
Keep the container tightly closed and in a cool, well-ventilated place. Keep away from heat, spark and flame.
Wash thoroughly after handling.
Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
This product may react with strong acids or oxidizing agents.
None under normal processing.
Keep away from heat, spark and flame.
Not available.
Upon decomposition, this product may yield sulfur dioxide, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- NA 1993
- Shipping Name
- Combustible liquid, n.o.s. (Petroleum distillates)
- Transport Class
- Combustible Liquid
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON known by?
BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON is also known as: VO-2CA
What is the hazard signal word for BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON?
The signal word is danger.
What is the physical form of BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON?
BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON is a liquid with amber color. It has solvent odor.
What is the solubility of BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON?
Negligible
What is BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON used for?
Corrosion Protection Oils
What are the hazard statements for BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON?
This substance has 2 hazard statements:
- H227: COMBUSTIBLE LIQUID.
- H304: MAY BE FATAL IF SWALLOWED AND ENTERS AIRWAYS.
What is the melting point of BONDERITE L-GP VO 2CA RUST PREVENTATIVE ACHESON?
The melting point is Not determined and the boiling point is 182 °C (359.6 °F)calculated.