Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134
Product Code
1224001

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Solvent

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Methanol 67-56-1 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Get medical attention. Wash clothing before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a closed container until ready for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Refer to Section 8.

Storage

Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep in a cool, well ventilated area away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Clear
Colour Intensity
---
Form
---
Odor
Sweet
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
100 °C (212°F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
0.1 mm hg
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.187
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Insoluble Water
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
1,186 g/l
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

High temperatures. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials.

Incompatible

Strong oxidizing agents. Strong acids and strong bases.

Decomposition

Oxides of carbon. Hydrocarbons. Irritating organic vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134?

The signal word is no signal word.

What is the physical form of LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134?

LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134 is a liquid with clear color. It has sweet odor.

What is the solubility of LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134?

Insoluble Water

What is LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134 used for?

Solvent

What is the melting point of LOCTITE EDAG 30C-134 E&C known as ELECTRODAG30C-134?

The melting point is Not available. and the boiling point is Not available..