NextSDS Logo
Safety Data Sheet EN

LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA
Product Code
1189067

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Silicone adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2A
STOT RE Cat. 2

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H319 CAUSES SERIOUS EYE IRRITATION.
H372 MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.

Precautionary Statements

P261 Do not breathe vapors, mist, or spray.
P264 Wash affected area thoroughly after handling.
P282 Wear eye and face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314 Get medical attention if you feel unwell.
P337 + P313 If eye irritation persists: Get medical attention.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Limestone 1317-65-3 10 - 30% Yes
Silicic acid, ethyl ester 11099-06-2 1 - 5% Yes
Diiron trioxide 1309-37-1 1 - 5% Yes
Silica, amorphous, diatomaceous earth 68855-54-9 1 - 5% Yes
tetraethyl silicate 78-10-4 1 - 5% Yes

IDH number: 1189067 Product name: LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Wash clothing before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Specific hazards

Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

isolate the hazard area and deny entry to unnecessary and unprotected personnel

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling.

Storage

Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep in a cool, well ventilated area away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
Not available.
Dynamic Viscosity
---
Ph
Not applicable
Vapor Pressure
Negligible vapor pressure at ambient temperatures.
Physical State Data
liquid
Flash Point
> 93.3 °C (> 199.94 °F)
Metal Corrosion
---
Bulk Density
---
Density
---
Solubility In Fat
---
Odor
Slight
Melting Point
Not applicable
Evaporation Rate
Not applicable
Partition Coefficient
Not determined
Auto Ignition Temperature
Not available.
Relative Evaporation Rate
---
State Under Standard Conditions
---
Form
---
Molecular Weight
---
Odor Threshold
Not available.
Crystallisation Point
---
Physical State
Liquid
Solubility In Water
Insoluble
Freezing Point
---
Colour
Red
Lower Explosive Limit
Not available.
Solubility
---
Vapor Density
Not determined
Appearance
---
Colour Intensity
---
Properties Status
---
Relative Density
1.2
Cloud Point
---
Voc Content
< 1.9 g/l
Boiling Point
Not applicable
Explosive Limits
---
Softening Point
---
Solidification Point
---
Kinematic Viscosity
---
Decomposition Temperature
Not available.
Flammability
Not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

Elevated temperatures. Store away from incompatible materials. Heat, flames, sparks and other sources of ignition.

Incompatible

Strong acids. Strong bases. Strong oxidizing agents.

Decomposition

Oxides of carbon. Oxides of silicon. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?

The signal word is warning.

What is the physical form of LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?

LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA is a liquid with red color. It has slight odor.

What is LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA used for?

Silicone adhesive

What are the hazard statements for LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?

This substance has 2 hazard statements:

  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H372: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.

What is the melting point of LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?

The melting point is Not applicable and the boiling point is Not applicable.