Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA
- Product Code
- 1189067
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Silicone adhesive
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Limestone | 1317-65-3 | 10 - 30% | Yes |
| Silicic acid, ethyl ester | 11099-06-2 | 1 - 5% | Yes |
| Diiron trioxide | 1309-37-1 | 1 - 5% | Yes |
| Silica, amorphous, diatomaceous earth | 68855-54-9 | 1 - 5% | Yes |
| tetraethyl silicate | 78-10-4 | 1 - 5% | Yes |
IDH number: 1189067 Product name: LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Do not induce vomiting. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
LOCTITE STYCAST 5952 RD PTA known as STYCAST 5952 PTA RED 15LB GA
---
LOCTITE STYCAST S 5225 PTA known as STYCAST S 5225 A (1.5lb)
---
LOCTITE STYCAST 5877 PTB
---
LOCTITE STYCAST ES 4412 PTA known as HYSOL ES4412 PART A GAL
---
LOCTITE STYCAST E 3450 PTB known as ECCOBOND E3450(B) (101292-008)
---
LOCTITE ABLESTIK SF 40 WH PTA known as ECCOBOND SF-40 PTA WHT 5LB GA
---
LOCTITE STYCAST EE 8016F
---
LOCTITE STYCAST 1265 CL PTB known as STYCAST 1265 PTB CLR 40LB PAIL
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling.
Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep in a cool, well ventilated area away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Will not occur.
Elevated temperatures. Store away from incompatible materials. Heat, flames, sparks and other sources of ignition.
Strong acids. Strong bases. Strong oxidizing agents.
Oxides of carbon. Oxides of silicon. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?
The signal word is warning.
What is the physical form of LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?
LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA is a liquid with red color. It has slight odor.
What is LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA used for?
Silicone adhesive
What are the hazard statements for LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?
This substance has 2 hazard statements:
- H319: CAUSES SERIOUS EYE IRRITATION.
- H372: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE STYCAST SC 71 PTA known as ECCOCOAT SC-71 PTA 4LB GA?
The melting point is Not applicable and the boiling point is Not applicable.