NextSDS Logo
Safety Data Sheet EN

DELETE BONDERITE M-CR 1402W PCC

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DELETE BONDERITE M-CR 1402W PCC
Product Code
2199028

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Conversion coating

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4
Acute Tox. Cat. 3
Skin Corr. Cat. 1
Eye Dam. Cat. 1
Skin Sens. Cat. 1
Carc. Cat. 1B

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS06 - Acute toxicity

GHS06

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 HARMFUL IF SWALLOWED.
H314 CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H331 TOXIC IF INHALED.
H350 MAY CAUSE CANCER.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P271 Use only outdoors or in a well-ventilated area.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303 + P361 + P353 If on skin (or hair): Take off immediately all contaminated clothing.
P304 + P340 + P310 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a POISON CENTER or physician.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical attention.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
IF SWALLOWED: Call a POISON CENTER or doctor/ physician if you feel unwell. Rinse mouth.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Chromium chromate 24613-89-6 5 - 10% Yes
Silica, amorphous, fumed, cryst.-free 112945-52-5 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist. Administer oxygen or artificial respiration as needed. Do not use mouth-to-mouth method if victim ingested or inhaled the substance.

Symptoms: Delayed effects possible after inhalation.

Skin contact

Remove contaminated clothing and footwear. Immediately wash skin thoroughly with soap and water. Launder contaminated clothing before reuse. Discard any shoes or clothing items that cannot be decontaminated.

Symptoms: chromate scabs and skin ulcers

Eye contact

Immediately flush affected eye with large amounts of gently flowing water or 0.9% sterile saline solution for at least 15 minutes. Hold eyelid wide open. Get immediate medical attention. Eye flushing should continue during transportation to a doctor.

Ingestion

Get immediate medical attention. Do not induce vomiting. If individual is conscious, wash out mouth with water. Provide a glass of water to dilute the material in the stomach.

Immediate Medical Attention

Get immediate medical attention.

Medical Treatment

Topical 10 % EDTA ointment can be used to treat chromate scabs and skin ulcers. A 10 % ascorbic acid solution may speed healing if applied promptly. Larger exposures may need additional treatment. Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Formation of toxic gases is possible during heating or in fires. May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.

Instructions

Wear full protective clothing. Wear self-contained breathing apparatus.

Firefighter Protection

Wear full protective clothing. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Absorb spill with inert material. Shovel material into appropriate container for disposal.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing vapors or mists of this product. Use only with adequate ventilation. Launder work clothes frequently. Do not store or consume food, drink, or tobacco products in areas where they may become contaminated with this material. Do not take internally. For industrial use only.

Storage

Store at or above 40 °F (4.4 °C). Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Protect from freezing, freezing temperature is <=32F (<=0C).

Hygiene

Wash thoroughly after handling. Launder work clothes frequently. Do not store or consume food, drink, or tobacco products in areas where they may become contaminated with this material.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Relative Evaporation Rate
---
Properties Status
---
Colour
Brown
Vapor Pressure
Not determined
Solubility In Fat
---
Density
---
Kinematic Viscosity
Not available.
Physical State Data
liquid
Boiling Point
> 100 °C (> 212°F)
Upper Explosive Limit
Not available.
Evaporation Rate
Not available.
Partition Coefficient
Not determined
Solubility In Water
---
Metal Corrosion
---
Lower Explosive Limit
Not available.
Decomposition Temperature
Not available.
Form
---
Solidification Point
---
Dynamic Viscosity
Not available.
Vapor Density
---
Melting Point
Not determined
Odor Threshold
Not available.
Auto Ignition Temperature
Not determined
Voc Content
Not applicable
State Under Standard Conditions
---
Softening Point
---
Ph
2.3 - 2.5
Flash Point
Not available.
Colour Intensity
---
Explosive Limits
---
Relative Density
1.11 - 1.14 at 60 °F (15.56 °C)
Bulk Density
---
Molecular Weight
---
Freezing Point
---
Odor
---
Flammability
Not applicable
Appearance
---
Crystallisation Point
---
Cloud Point
---
Solubility
Complete Water
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Store away from incompatible materials.

Incompatible

This product may react with strong reducing agents. Keep away from organic and combustible materials. Strong bases. Metals.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Chromium oxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
Environmentally hazardous substance, liquid, n.o.s. (Chromium(III)-chromate)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DELETE BONDERITE M-CR 1402W PCC?

The signal word is danger.

What is the physical form of DELETE BONDERITE M-CR 1402W PCC?

DELETE BONDERITE M-CR 1402W PCC is a liquid with brown color.

What is the solubility of DELETE BONDERITE M-CR 1402W PCC?

Complete Water

What is DELETE BONDERITE M-CR 1402W PCC used for?

Conversion coating

What are the hazard statements for DELETE BONDERITE M-CR 1402W PCC?

This substance has 5 hazard statements:

  • H302: HARMFUL IF SWALLOWED.
  • H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H331: TOXIC IF INHALED.
  • H350: MAY CAUSE CANCER.

What is the melting point of DELETE BONDERITE M-CR 1402W PCC?

The melting point is Not determined and the boiling point is > 100 °C (> 212°F).