Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE CAT 50 AMB known as CATALYST 50 AMB 10 GR
- Product Code
- 1188198
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS06
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Butoxydibutylchlorostannane | 14254-22-9 | 80 - 90% | No |
| 2-Butoxyethanol | 111-76-2 | 5 - 10% | No |
| Hydrochloric acid | 7647-01-0 | 1 - 5% | No |
| n-Butyl alcohol | 71-36-3 | 1 - 5% | No |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Never give anything by mouth to an unconscious person. Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, dry chemical or carbon dioxide.
Do not use water.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat. Vapours may accumulate in low or confined areas, travel considerable distance to source of ignition, and flash back.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up as much material as possible.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE CAT 9 AMB known as CATALYST 9 AMB 1LB
---
LOCTITE CAT B 97 known as CATALYST B-97 (25g)
---
LOCTITE CAT 23LVJ known as CATALYST 23LVJ 0.2kg
---
LOCTITE CAT 24LV CL known as CATALYST 24LV CLR 1LB INDIVIDUAL
---
LOCTITE 609 BO50MLEN
---
LOCTITE 510
---
LOCTITE AA 326 BO50G CX6UN
---
LOCTITE ABLESTIK CDF 200 50 PER RL
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling.
Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Avoid moisture. High temperatures. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials.
Strong acids and strong bases. Oxidizing agents. Water Incompatible with ferrous metals. Reactive metals.
Oxides of carbon. Oxides of nitrogen. Irritating organic vapours. Hazardous decomposition products include chlorine compounds. Hydrocarbons. Oxides of tin.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2924
- Shipping Name
- Flammable liquids, corrosive, n.o.s. (Butoxydibutylchlorostannane, 1-Butanol)
- Transport Class
- 3 (8)
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE CAT 50 AMB known as CATALYST 50 AMB 10 GR?
The signal word is danger.
What is the physical form of LOCTITE CAT 50 AMB known as CATALYST 50 AMB 10 GR?
LOCTITE CAT 50 AMB known as CATALYST 50 AMB 10 GR is a liquid with yellow color. It has pungent odor.
What are the hazard statements for LOCTITE CAT 50 AMB known as CATALYST 50 AMB 10 GR?
This substance has 4 hazard statements:
- H226: FLAMMABLE LIQUID AND VAPOR.
- H301: TOXIC IF SWALLOWED.
- H315: CAUSES SKIN IRRITATION.
- H318: CAUSES SERIOUS EYE DAMAGE.
What is the melting point of LOCTITE CAT 50 AMB known as CATALYST 50 AMB 10 GR?
The melting point is Not applicable and the boiling point is 121 °C (249.8 °F).