NextSDS Logo
Safety Data Sheet EN

LOCTITE CAT B 97 known as CATALYST B-97 (25g)

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE CAT B 97 known as CATALYST B-97 (25g)
Product Code
1188349

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Catalyst

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4
Eye Dam. Cat. 1
STOT SE Cat. 1

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 HARMFUL IF SWALLOWED.
H318 CAUSES SERIOUS EYE DAMAGE.
H370 CAUSES DAMAGE TO ORGANS.

Precautionary Statements

P261 Do not breathe vapors, mist, or spray.
P264 Wash affected area thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P282 Wear eye and face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth.
P307 + P311 If exposed: Call a poison center or physician.
P331 Do NOT induce vomiting.
P338 Remove contact lenses, if present and easy to do.
P338 Continue rinsing.
P351 IF IN EYES: Rinse cautiously with water for several minutes.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Reaction mass of 2-ethyl-4-methyl-1H-imidazole-1-propiononitrile and 2-ethyl-5-methyl-1H-imidazole-1-propiononitrile 568591-00-4 80 - 100% Yes
Imidazole derivative --- 1 - 5% Yes
Methanol 67-56-1 1 - 5% Yes

IDH number: 1188349 Product name: LOCTITE CAT B 97 known as CATALYST B-97 (25g)

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Specific hazards

Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Remove all sources of ignition. Ensure adequate ventilation. Isolate area. Keep unnecessary personnel away. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a closed container until ready for disposal.

Materials: sand, silica gel, acid binder, universal binder, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling.

Storage

Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep in a cool, well ventilated area away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility
---
Metal Corrosion
---
Odor
Amine
Crystallisation Point
---
Freezing Point
---
Dynamic Viscosity
---
Bulk Density
---
Flammability
Not applicable
Form
---
Decomposition Temperature
Not available.
Vapor Density
5.67
Upper Explosive Limit
Not available.
Appearance
---
Colour Intensity
---
Ph
Not available.
Vapor Pressure
8.89 mm hg
Auto Ignition Temperature
Not available.
Flash Point
176 °C (348.8 °F) Cleveland open cup
Cloud Point
---
Explosive Limits
---
Properties Status
---
Melting Point
Not available.
Relative Evaporation Rate
---
Solubility In Water
Partially soluble
Solubility In Fat
---
Voc Content
0.05 %; 5 g/l (by weight)
Kinematic Viscosity
---
State Under Standard Conditions
---
Relative Density
0.95
Physical State Data
liquid
Colour
Yellow
Physical State
Liquid
Partition Coefficient
Not available.
Boiling Point
Not available.
Evaporation Rate
Not available.
Molecular Weight
---
Lower Explosive Limit
Not available.
Solidification Point
---
Density
---
Odor Threshold
Not available.
Softening Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

High temperatures. Store away from incompatible materials. Heat, flames, sparks and other sources of ignition.

Incompatible

Strong oxidizing agents.

Decomposition

Oxides of carbon. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE CAT B 97 known as CATALYST B-97 (25g)?

The signal word is danger.

What is the physical form of LOCTITE CAT B 97 known as CATALYST B-97 (25g)?

LOCTITE CAT B 97 known as CATALYST B-97 (25g) is a liquid with yellow color. It has amine odor.

What is LOCTITE CAT B 97 known as CATALYST B-97 (25g) used for?

Catalyst

What are the hazard statements for LOCTITE CAT B 97 known as CATALYST B-97 (25g)?

This substance has 3 hazard statements:

  • H302: HARMFUL IF SWALLOWED.
  • H318: CAUSES SERIOUS EYE DAMAGE.
  • H370: CAUSES DAMAGE TO ORGANS.

What is the melting point of LOCTITE CAT B 97 known as CATALYST B-97 (25g)?

The melting point is Not available. and the boiling point is Not available..