NextSDS Logo
Safety Data Sheet EN

LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)
Product Code
1201285

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Acrylic Adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 4
Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Skin Sens. Cat. 1
Repr. Cat. 2
STOT SE Cat. 3

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H227 COMBUSTIBLE LIQUID.
H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H335 MAY CAUSE RESPIRATORY IRRITATION.
H361 SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical attention.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or physician if you feel unwell.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2,2,3,3,4,4,5,5-Octafluoropentyl methacrylate 355-93-1 30 - 60% Yes
Polycarbonate polyurethane acrylate polymer~ 145268-21-9 30 - 60% Yes
Polyester acrylate (multi-functional)~ --- 5 - 10% Yes
Hydroxyalkyl methacrylate 27813-02-1 5 - 10% Yes
Gamma-glycidoxypropyl trimethoxysilane 2530-83-8 1 - 5% Yes
diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide 75980-60-8 1 - 5% Yes
Tert-butyl perbenzoate 614-45-9 0.1 - 1% Yes
Polypropylene glycol monomethacrylate 39420-45-6 0.1 - 1% Yes
methacrylic acid 79-41-4 0.1 - 1% Yes

Non hazardous components

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol-resistant foam. Carbon dioxide. Dry powder. Water spray or fog.

Unsuitable media

High pressure waterjet

Specific hazards

Vapors are heavier than air and may travel along the ground or be moved by ventilation and subsequently ignited by heat, pilot lights or other ignition sources at locations distant from the material handling point. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a closed container until ready for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep area ventilated - do not smoke; extinguish all flames, pilot lights, and heaters; turn off stoves, electrical tools and appliances, and any other sources of ignition. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Wear suitable protective clothing, safety glasses and gloves.

Storage

Store between -20 °C (-4°F) and 50 °C (122°F). Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Protect from direct sunlight. Maintain head space in storage containers to support oxygen requirements of the inhibitor(s).

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame. Keep area ventilated - do not smoke; extinguish all flames, pilot lights, and heaters; turn off stoves, electrical tools and appliances, and any other sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless / Colorless
Colour Intensity
---
Form
---
Odor
Slight
Odor Threshold
Not available.
Ph
Not applicable, Product is non-soluble (in water).
Melting Point
Not applicable, Product is a liquid
Boiling Point
Not applicable, Polymerization can occur at greater than 150°C (302°F).
Flash Point
76.1 °C (168.98 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
< 3.0 hPa (20 °C (68°F))
Vapor Density
---
Relative Density
1.1
Bulk Density
---
Density
---
Flammability
The product is not flammable.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
> 200 °C
Solubility
Insoluble Water
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
41.2 % (by weight)
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
1,250 mm2/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

May occur with excessive aging, excessive heat, polymerization catalyst, inhibitor depletion, direct sunlight and under oxygen-free atmospheres.

Avoid

Keep away from heat, ignition sources and incompatible materials. Protect from direct sunlight. UV light. Loss of polymerization inhibitor. Loss of dissolved air.

Incompatible

Strong oxidizing agents. Strong reducing agents. Strong acids and strong bases. Free radical initiators. Organic peroxides. Amines. Sulfur. Mineral acids. Alkalis. Water.

Decomposition

Oxides of carbon. Oxides of nitrogen. Cyanides. Hydrogen fluoride. Oxides of silicon. Formaldehyde. Thermal decomposition may produce methanol. Toxic fumes. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
NA 1993
Shipping Name
Combustible liquid, n.o.s. (Acrylate mixture)
Transport Class
Combustible Liquid
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)?

The signal word is warning.

What is the physical form of LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)?

LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g) is a liquid with colourless / colorless color. It has slight odor.

What is the solubility of LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)?

Insoluble Water

What is LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g) used for?

Acrylic Adhesive

What are the hazard statements for LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)?

This substance has 6 hazard statements:

  • H227: COMBUSTIBLE LIQUID.
  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H335: MAY CAUSE RESPIRATORY IRRITATION.
  • H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.

What is the melting point of LOCTITE ECCOBOND LUX UV90 known as Ablelux UV90 (12g)?

The melting point is Not applicable, Product is a liquid and the boiling point is Not applicable, Polymerization can occur at greater than 150°C (302°F)..