Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C
- Product Code
- 288716
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cored solder wire
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.
Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If symptoms develop and persist, get medical attention.
Immediate Medical Attention
If symptoms develop and persist, get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear. Do not use water on fires where molten metal is present.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Ensure adequate ventilation. Scrape up spilled material and place in a closed container for disposal.
Related Products
Similar products with comparable safety profiles
LOCTITE C 511 96SC 3C 0.23MM GN known as 96SC CRYSTAL 511 3C
---
LOCTITE C 511 99C 5C 1.6MM K known as 99C C511 5C 1.6MM DIN 2KG
---
LOCTITE 105 60EN 5C 0.7MM SA
---
LOCTITE C 400 SN62 5C 0.32MM RF known as SN62 CRYSTAL 400 5C
---
LOCTITE 362 60EN 5C 0.7MM S
---
LOCTITE SI 5140 CR300ML
---
LOCTITE 510
---
LOCTITE SI 5145
UFI: K2GW-MWCE-8206-CXKD
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear suitable protective clothing, gloves and eye/face protection. Avoid skin contact with molten resins. Avoid contact with eyes, skin and clothing.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store in original container until ready to use.
When using, do not eat, drink or smoke. Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Not available.
Will not occur.
Solder alloy will react with concentrated nitric acid to produce toxic fumes of nitrogen oxides.
Strong oxidizing agents. Strong acids and strong bases.
Oxides of carbon. Metal oxide fumes. Formaldehyde. Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C?
The signal word is danger.
What is the physical form of LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C?
LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C is a solid with gray / grey color. It has mild odor.
What is the solubility of LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C?
Negligible
What is LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C used for?
Cored solder wire
What are the hazard statements for LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C?
This substance has 5 hazard statements:
- H302 + H332: HARMFUL IF SWALLOWED OR IF INHALED.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H336: MAY CAUSE DROWSINESS OR DIZZINESS.
- H360: MAY DAMAGE FERTILITY OR THE UNBORN CHILD.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE C 511 60EN 5C 0.7MM R known as 60EN CRYSTAL 511 5C?
The melting point is 183 - 188 °C (361.4 - 370.4 °F); 217 °C (422.6 °F) (solder alloy) and the boiling point is Not determined Flux chars above 250°C (485°F).