01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan
Product Form
Ultraviolet adhesive
Product Code
19870

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Corr. Cat. 1B
Eye Dam. Cat. 1
Skin Sens. Cat. 1

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H314 CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.

Precautionary Statements

P261 Do not breathe vapors, mist, or spray.
P264 Wash thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, eye protection, and face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to remove. Continue rinsing.
P310 Immediately call a poison control center or physician.
P331 Do NOT induce vomiting.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P361 If on skin (or hair): Take off immediately all contaminated clothing.
P363 Wash contaminated clothing before reuse.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Polyurethane Methacrylate Resin --- 30 - 60% Yes
High boiling methacrylate --- 10 - 30% Yes
Hydroxyalkyl methacrylate 27813-02-1 10 - 30% Yes
Lauryl methacrylate 142-90-5 5 - 10% Yes
Photoinitiator 24650-42-8 5 - 10% Yes
Acrylic acid 79-10-7 5 - 10% Yes
Tetradecyl methacrylate 2549-53-3 1 - 5% Yes
Alkyl Methacrylate --- 1 - 5% Yes
Substituted silane --- 1 - 5% Yes
Substituted Silane --- 0.1 - 1% Yes
Adhesion Promoter --- 0.1 - 1% Yes
Polyglycol dimethacrylate --- 0.1 - 1% Yes

IDH number: 303012 Product name: LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan

Notes

* Exact percentage is a trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Wash clothing before reuse. Get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Specific hazards

Uncontrolled polymerization may occur at high temperatures resulting in explosions or rupture of storage containers.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up as much material as possible.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Do not taste or swallow. DO NOT heat or spray. Refer to Section 8.

Storage

Store at or below 38 °C (100.4 °F). Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep in a cool, well ventilated area away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Clear
Colour Intensity
---
Form
---
Odor
Sharp, Irritating
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
Not available.
Boiling Point
> 149.0 °C (> 300.2 °F)
Flash Point
> 93.3 °C (> 199.94 °F) Tagliabue closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
< 10 mm hg (27.0 °C (80.6 °F))
Vapor Density
Not available.
Relative Density
1.1
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not available.
Solubility In Water
Slight
Solubility In Fat
---
Molecular Weight
---
Voc Content
Not available.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing. Polymerization may occur at elevated temperature or in the presence of incompatible materials.

Avoid

Elevated temperatures. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials.

Incompatible

Strong oxidizing agents. Strong reducing agents. Acids. Alkalis. Oxygen scavengers. Other polymerization initiators.

Decomposition

Oxides of carbon. Irritating organic vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
Environmentally hazardous substance, liquid, n.o.s. (2,2-Dimethoxy-1,2-diphenylethan-1-one, Isobornyl acrylate)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan?

The signal word is danger.

What is the physical form of LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan?

LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan is a liquid with clear color. It has sharp, irritating odor.

What are the hazard statements for LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan?

This substance has 2 hazard statements:

  • H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.

What is the melting point of LOCTITE AA LP-92 known as Loctite 190465 LP-92 Japan?

The melting point is Not available. and the boiling point is > 149.0 °C (> 300.2 °F).