Product Name
Phoenix 120 K

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Shielded Metal Arc Welding Electrode

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

voestalpine Böhler Welding Austria GmbH logo

voestalpine Böhler Welding Austria GmbH

manufacturer

Böhler-Welding-St. 1, 8605 Kapfenberg

+43/50304/31-0

https://www.voestalpine.com/welding

Emergency Contacts

Carechem24

+44 1235 239670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
manganese EC: 231-105-1 7439-96-5 0.1 - 2.5% Yes
titanium dioxide EC: 236-675-5 13463-67-7 0.1 - 2.5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Suitable to surrounding conditions.

Unsuitable media

water or halogenated containing extinguishing agents

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure that suitable extractors are available on processing machines

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

EN 12477 Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Filter P2

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
According to product specification
Colour Intensity
---
Form
Solid
Odor
Odourless
Odor Threshold
Not determined
Ph
Not applicable
Melting Point
---
Boiling Point
---
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
---
Vapor Density
Not applicable
Relative Density
Not determined
Bulk Density
---
Density
Not determined
Flammability
Not determined
Upper Explosive Limit
Not determined
Lower Explosive Limit
Not determined
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined
Solubility
---
Partition Coefficient
Not determined
Solubility In Water
Insoluble.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
Void
Dynamic Viscosity
Not applicable
Kinematic Viscosity
Not applicable
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used and stored according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

Attacks materials containing glass and silicate.

Avoid

No decomposition if used and stored according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Phoenix 120 K?

The signal word is no signal word.

What is the physical form of Phoenix 120 K?

Phoenix 120 K is a solid with according to product specification color. It has odourless odor.

What is Phoenix 120 K used for?

Shielded Metal Arc Welding Electrode