NextSDS Logo
Safety Data Sheet EN

OP 121TT

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
OP 121TT

Regulatory Identifiers

CAS Number
N/A
UFI Code
GSMN-J9GQ-M900-8GC8

Identified Uses

SAW (Submerged Arc Welding)

Uses advised against

Not known. Read this SDS before using this product.

Manufacturers & Suppliers

Lincoln Electric Europe B.V. logo

Lincoln Electric Europe B.V.

manufacturer

Nieuwe Dukenburgseweg 20, Nijmegen 6534AD, The Netherlands

+31 243 522 911

http://www.lincolnelectric.com/sds

Emergency Contacts

USA/Canada/Mexico

+1 (888) 609-1762

Americas/Europe

+1 (216) 383-8962

Asia Pacific

+1 (216) 383-8966

Middle East/Africa

+1 (216) 383-8969

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Lithium silicate EC: 233-270-5 10102-24-6 1 - 5% Yes
Calcium fluoride EC: 232-188-7 7789-75-5 20 - 50% No
Potassium silicate EC: 215-199-1 1312-76-1 1 - 5% Yes
Calcium oxide EC: 215-138-9 1305-78-8 1 - 5% Yes
Sodium silicate EC: 215-687-4 1344-09-8 1 - 5% Yes
Quartz EC: 238-878-4 14808-60-7 0.1 - 1% Yes

Notes

The term “Hazardous Ingredients” should be interpreted as a term defined in Hazard Communication standards and does not necessarily imply the existence of a welding or allied process hazard. The product may contain additional non-hazardous ingredients or may form additional compounds under the condition of use. Refer to Sections 2 and 8 for more information.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air if breathing is difficult. If breathing has stopped, perform artificial respiration and obtain medical assistance at once.

Symptoms: Short-term (acute) overexposure to fumes and gases from welding and allied processes may result in discomfort such as metal fume fever, dizziness, nausea, or dryness or irritation of nose, throat, or eyes. May aggravate pre-existing respiratory problems (e.g. asthma, emphysema). Long-term (chronic) overexposure to fumes and gases from welding and allied processes can lead to siderosis (iron deposits in lung), central nervous system effects, bronchitis and other pulmonary effects.

Skin contact

Remove contaminated clothing and wash the skin thoroughly with soap and water. Obtain medical assistance at once.

Symptoms: Reddened or blistered skin, or thermal burns.

Eye contact

Dust or fume from this product should be flushed from the eyes with copious amounts of clean, tepid water until transported to an emergency medical facility. Obtain medical assistance at once. If exposed to arc rays, move victim to dark room, remove contact lenses as necessary for treatment, cover eyes with a padded dressing and rest.

Symptoms: Arc rays can injure eyes.

Ingestion

Avoid hand, clothing, food, and drink contact with fluxes, metal fume or powder which can cause ingestion of particulate during hand to mouth activities such as drinking, eating, smoking, etc. If ingested, do not induce vomiting. Contact a poison control center. Unless the poison control center advises otherwise, wash out mouth thoroughly with water. If symptoms develop, seek medical attention at once.

Immediate Medical Attention

Obtain medical assistance at once for inhalation, skin contact, eye contact, and ingestion if symptoms develop.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

As shipped, the product will not burn. In case of fire in the surroundings: use appropriate extinguishing agent.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

Welding arc and sparks can ignite combustibles and flammable products.

Instructions

Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection

Selection of respiratory protection for fire fighting: follow the general fire precautions indicated in the workplace. Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

If airborne dust and/or fume is present, use adequate engineering controls and, if needed, personal protection to prevent overexposure. Refer to recommendations in Section 8.

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Absorb with sand or other inert absorbent. Clean up spills immediately.

Materials: sand or other inert absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Read and understand the manufacturer's instruction and the precautionary label on the product.

Storage

Store in closed original container in a dry place. Store in accordance with local/regional/national regulations.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use enough ventilation and local exhaust at the arc, flame or heat source to keep the fumes and gases from the worker's breathing zone and the general area. Train the operator to keep their head out of the fumes. Keep exposure as low as possible.

Hands

Wear protective gloves. Suitable gloves can be recommended by the glove supplier.

Eyes

Wear helmet or use face shield with filter lens shade number 12 or darker for open arc processes – or follow the recommendations as specified in ANSI Z49.1, Section 4, based on your process and settings. No specific lens shade recommendation for submerged arc or electroslag processes. Shield others by providing appropriate screens and flash goggles.

Respiratory

Keep your head out of fumes. Use enough ventilation and local exhaust to keep fumes and gases from your breathing zone and the general area. An approved respirator should be used unless exposure assessments are below applicable exposure limits.

Skin/Body

Wear hand, head, and body protection which help to prevent injury from radiation, open flames, hot surfaces, sparks and electrical shock. See Z49.1. At a minimum, this includes welder's gloves and a protective face shield when welding, and may include arm protectors, aprons, hats, shoulder protection, as well as dark substantial clothing when welding, brazing and soldering. Wear dry gloves free of holes or split seams. Train the operator not to permit electrically live parts or electrodes from contacting the skin . . . or clothing or gloves if they are wet. Insulate yourself from the work piece and ground using dry plywood, rubber mats or other dry insulation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Granular welding flux.
Colour
Grey
Colour Intensity
---
Form
Granular
Odor
No data available.
Odor Threshold
No data available.
Ph
Not applicable
Melting Point
No data available.
Boiling Point
No data available.
Flash Point
No data available.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available.
Vapor Pressure
No data available.
Vapor Density
---
Relative Density
No data available.
Bulk Density
Not available.
Density
2,0 g/cm3
Flammability
No data available.
Upper Explosive Limit
No data available.
Lower Explosive Limit
No data available.
Explosive Limits
---
Auto Ignition Temperature
No data available.
Decomposition Temperature
No data available.
Solubility
---
Partition Coefficient
No data available.
Solubility In Water
No data available.
Solubility In Fat
---
Molecular Weight
---
Voc Content
Not available.
Metal Corrosion
Not available.
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

None under normal conditions.

Avoid

Avoid heat or contamination.

Incompatible

Strong acids. Strong oxidizing substances. Strong bases.

Decomposition

Fumes and gases from welding and its allied processes such as brazing and soldering. Reasonably expected fume constituents produced during arc welding and brazing include the oxides of iron, manganese and other metals present in the welding consumable or base metal. Hexavalent chromium compounds may be in the welding or brazing fume of consumables or base metals which contain chromium. Gaseous and particulate fluoride may be in the fume of consumables or flux materials which contain fluoride. Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may be formed by the radiation from the arc associated with welding.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for OP 121TT?

The signal word is no signal word.

What is the physical form of OP 121TT?

OP 121TT is a solid appearing as granular welding flux. with grey color. It has no data available. odor.

What is OP 121TT used for?

SAW (Submerged Arc Welding)

What is the melting point of OP 121TT?

The melting point is No data available. and the boiling point is No data available..