NextSDS Logo
Safety Data Sheet EN

FBS -1 Rockwool Insulation

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FBS -1 Rockwool Insulation
Product Code
Fibertex, Fibermesh, Fireseal
Synonyms
FBS-1 Rockwool Batts, Fibermesh 350/ 450/ 650/ 820/HD, Fibertex 350/ 450/ 650/ 820/HD (board, blanket & strip), Growool, Building granulated, Industrial granulated, Industrial HP granulated, Sectional Pipe Insulation, Curtain wall batts, Party wall batts, Fire Damper strips, FZ Batts, Party wall sealer, Batten fillers, SPI Block, Rockwool Slab, Rockwool Block.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Thermal and acoustic insulation, including fire protection and energy conservation. Used in homes, public and commercial buildings, warehouses, industrial and petrochemical plants, motor vehicles, ships, public transport, marine, power station and whitegoods. Also used as a hydroponic growing medium.

Manufacturers & Suppliers

C

CSR Building Products Limited

manufacturer

Triniti 3, 39 Delhi Road North Ryde NSW 2113 Australia

+61 2 9235 8000

Emergency Contacts

Fire Brigade and Police

000

Poisons Information Centre

13 11 26

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mineral rockwool fibre (amorphous, non-crystalline, bio-soluble – Note Q applicable) --- 85% No
Heat-cured resin (fibre binding agent) 25104-55-6 15% No
Mineral oil (solvent-refined dust suppression agent) 8012-95-1 2% No

Notes

Note: Traces (<0.1%) of volatile original components of resin may remain in recently manufactured product.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If symptoms persist, seek medical attention.

Skin contact

Flush off with water, preferably running. If itch or discomfort persists, seek medical attention.

Symptoms: Can be slightly itchy on prolonged contact with skin.

Eye contact

Flush with clean water. If discomfort persists, seek medical attention.

Ingestion

Rinse lips and mouth with water.

Medical Treatment

Treatment should be directed toward cleansing the skin and symptomatic treatment as necessary.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

As needed for surrounding fire conditions. Any extinguishing media may be used as required. Waterfog may be used to cool intact containers and nearby storage areas.

Specific hazards

FBS-1 Rockwool Insulation is non-flammable, but the plastic wrapping, resin binder, and some facings may decompose, smoulder or burn in a fire or when heated above 300°C. If product is present in a fire, toxic gases or smoke may be evolved depending on surrounding fire conditions.

Instructions

As needed for surrounding fire conditions. If required, evacuate area and contact emergency services; remain upwind and notify those downwind of fire hazard; and wear protective equipment including Self-Contained Breathing Apparatus (SCBA).

Firefighter Protection

wear protective equipment including Self-Contained Breathing Apparatus (SCBA)

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Cleanup methods

Clean area so as to avoid dispersion of loose material or fibres using wet sweep methods or vacuum cleaner.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Minimise eye or skin contact and inhalation during handling, installation and removal (see Section 8).

Storage

Store in sealed container in cool, dry area, removed from foodstuffs. Ensure packages are adequately labelled, protected from physical damage, and sealed when not in use. Avoid packaging being stored under UV light (direct sunlight) for long periods.

Hygiene

Observe good personal hygiene, including washing hands before eating. Remove personal protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

During most applications and installation no special ventilation will be required. However, if installing in dusty or poorly-ventilated areas, or during the first heat-up cycle in high-temperature industrial applications, local exhaust ventilation should be considered. Work practices should aim to minimise the release of, and exposure to, fibres and/or dust. Hand tools generate the least amount of dust and fibres. If power tools are used directly on the product appropriate dust collection systems are recommended.

Hands

Standard duty gloves conforming to Australian Standard AS 2161. Bradford Comfortsleeve™ gloves are recommended for improved comfort when handling and installing Rockwool Insulation.

Eyes

When handling these products, particularly overhead or in enclosed or poorly-ventilated areas such as ceiling spaces or risers, eye contact with dust or fibre can be avoided by wearing ventilated non-fogging dust resistant goggles conforming to Australian and New Zealand Standards AS/NZS 1336.

Respiratory

None normally required. If dust is generated in enclosed or poorly-ventilated areas, an approved particulate respirator conforming to Australian and New Zealand Standards AS/NZS 1715 and 1716 is recommended. P1, P2 or N95 type respirators are appropriate. Use only respirators that bear the Australian Standards mark and are fitted and maintained correctly, and kept in clean storage when not in use.

Skin/Body

Direct skin contact can be minimised by wearing long-sleeved shirts and long trousers, a cap or hat, and standard duty gloves conforming to Australian Standard AS 2161. Work clothes should be washed regularly and separately from other clothes.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Metal Corrosion
---
Colour
---
Odor Threshold
---
State Under Standard Conditions
---
Cloud Point
---
Form
---
Freezing Point
---
Upper Explosive Limit
Not applicable
Decomposition Temperature
Up to 820°C (Dependent on product) – contact your local Bradford office or refer operating temperatures on data sheets for further information (Binder decomposition at 150°C)
Solubility In Fat
---
Physical State
solid
Vapor Density
---
Voc Content
Very low; <1% (Actual recorded value below detection limit for test method)
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Molecular Weight
---
Lower Explosive Limit
Not applicable
Evaporation Rate
---
Solubility
---
Kinematic Viscosity
---
Colour Intensity
---
Density
---
Melting Point
>1000°C
Appearance
A matt of brown or greyish fibrous material resembling wool. It is supplied in different shapes and sizes wrapped in plastic. It may be rigid or flexible. Facings such as aluminium foil, calico, wire, and synthetic tissues are applied to meet specific purposes.
Solidification Point
---
Ph
Not applicable
Solubility In Water
Negligible
Vapor Pressure
Not applicable
Bulk Density
---
Properties Status
---
Softening Point
---
Physical State Data
solid
Flammability
---
Relative Evaporation Rate
---
Flash Point
Not applicable
Relative Density
Generally low, but variable depending on facings
Odor
Usually odourless but may have faint amine odour
Crystallisation Point
---
Partition Coefficient
---
Boiling Point
Not applicable
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable. The cured resin is stable and will remain intact for the life of the product under normal atmospheric conditions.

Incompatible

No reported incompatibilities. Acids, alkalis or organic solvents may cause

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is FBS -1 Rockwool Insulation known by?

FBS -1 Rockwool Insulation is also known as: FBS-1 Rockwool Batts, Fibermesh 350/ 450/ 650/ 820/HD, Fibertex 350/ 450/ 650/ 820/HD (board, blanket & strip), Growool, Building granulated, Industrial granulated, Industrial HP granulated, Sectional Pipe Insulation, Curtain wall batts, Party wall batts, Fire Damper strips, FZ Batts, Party wall sealer, Batten fillers, SPI Block, Rockwool Slab, Rockwool Block.

What is the hazard signal word for FBS -1 Rockwool Insulation?

The signal word is no signal word.

What is the physical form of FBS -1 Rockwool Insulation?

FBS -1 Rockwool Insulation is a solid appearing as a matt of brown or greyish fibrous material resembling wool. it is supplied in different shapes and sizes wrapped in plastic. it may be rigid or flexible. facings such as aluminium foil, calico, wire, and synthetic tissues are applied to meet specific purposes. . It has usually odourless but may have faint amine odour odor.

What is FBS -1 Rockwool Insulation used for?

Thermal and acoustic insulation, including fire protection and energy conservation. Used in homes, public and commercial buildings, warehouses, industrial and petrochemical plants, motor vehicles, ships, public transport, marine, power station and whitegoods. Also used as a hydroponic growing medium.

What is the melting point of FBS -1 Rockwool Insulation?

The melting point is >1000°C and the boiling point is Not applicable.