01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Mannok Insulation - Polyisocyanurate Foam

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Thermal Insulation

Manufacturers & Suppliers

M

Mannok Insulation Ltd

manufacturer

Scotchtown, Ballyconnell, Co. Cavan Ireland

+353 (0) 49 952 5600

Emergency Contacts

Emergency Contact

0035 3872 698728

06:00 to 23:45

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
POLYISOCYANURATE FOAM --- 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move the exposed person to fresh air at once. Get medical attention if any discomfort continues.

Symptoms: Unlikely route of exposure as the product does not contain volatile substances.

Skin contact

Wash skin with soap and water. Get medical attention if any discomfort continues.

Eye contact

Promptly wash eyes with plenty of water while lifting the eye lids. Get medical attention if any discomfort continues.

Symptoms: Due to the physical form of the product, entry into the eyes is highly unlikely.

Ingestion

Immediately rinse mouth and provide fresh air. Get medical attention if any discomfort continues.

Symptoms: Due to the physical form of the product, accidental ingestion is highly unlikely.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water. Foam, carbon dioxide or dry powder.

Specific hazards

In case of fire, toxic and corrosive gases may be formed.

Firefighter Protection

Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

For dust generated by cutting or grinding panels: Avoid inhalation of dust. Avoid contact with skin and eyes.

Environmental

The product is not expected to be hazardous to the environment.

Cleanup methods

For dust generated by cutting or grinding panels: Collect powder using special dust vacuum cleaner with particle filter or carefully sweep into closed container.

Materials: special dust vacuum cleaner with particle filter, closed container

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe workplace exposure limits and minimise the risk of inhalation of dust.

Storage

Store in a dry place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Rigid boards
Colour
Yellow to Light brown
Colour Intensity
---
Form
---
Odor
Odourless
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
0.03 - 0.15
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
Insoluble in water
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal temperature conditions and recommended use.

Hazardous reactions

Will not polymerise.

Avoid

Avoid contact with water/moisture for prolonged periods.

Incompatible

Strong oxidising substances.

Decomposition

During fire, toxic gases (CO, CO2, NOx) are formed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.6 Endocrine disrupting properties

Not specified.

12.7 Other adverse effects

Not specified.

12.4 Mobility in soil

The product is non-volatile. The product is insoluble in water.

12.1 Toxicity

The product is not expected to be hazardous to the environment. Not considered toxic to fish.

12.2 Persistence and degradability

The product is not readily biodegradable.

12.3 Bioaccumulative potential

The product does not contain any substances expected to be bioaccumulating.

12.5 Results of PBT and vPvB assessment

Not specified.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of waste and residues in accordance with local authority requirements.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Not classified.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Mannok Insulation - Polyisocyanurate Foam?

The signal word is no signal word.

What is the physical form of Mannok Insulation - Polyisocyanurate Foam?

Mannok Insulation - Polyisocyanurate Foam is a solid appearing as rigid boards with yellow to light brown color. It has odourless odor.

What is the solubility of Mannok Insulation - Polyisocyanurate Foam?

Insoluble in water

What is Mannok Insulation - Polyisocyanurate Foam used for?

Thermal Insulation