NextSDS Logo
Safety Data Sheet EN

Scotch 1625 Contact Cleaner

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Scotch 1625 Contact Cleaner
Product Code
DE-9999-5338-8

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Electrical equipment cleaning

Manufacturers & Suppliers

3M United Kingdom PLC logo

3M United Kingdom PLC

national supplier

3M Centre, Cain Road, Bracknell, Berkshire, RG12 8HT.

+44 (0)1344 858 000

http://www.3M.com/uk

Emergency Contacts

Emergency Contact

+44 (0)1344 858 000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Eye Irrit. Cat. 2 H319
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container. may burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50C/122F.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Avoid breathing vapour or spray.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Naphtha (petroleum), hydrotreated light 64742-49-0 60 - 90% Yes
Propan-2-ol EC: 200-661-7 67-63-0 7 - 13% Yes
Butane EC: 203-448-7 106-97-8 5 - 10% Yes
Propane EC: 200-827-9 74-98-6 1 - 5% Yes
Carbon dioxide EC: 204-696-9 124-38-9 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air.

Skin contact

Immediately wash with soap and water. Remove contaminated clothing and wash before reuse.

Eye contact

Immediately flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing.

Ingestion

Rinse mouth.

Immediate Medical Attention

Get medical attention. If signs/symptoms develop, get medical attention. If you feel unwell, get medical attention.

Medical Treatment

Exposure may increase myocardial irritability.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use a fire fighting agent suitable for the surrounding fire.

Unsuitable media

Water may not effectively extinguish fire.

Specific hazards

Closed containers exposed to heat from fire may build pressure and explode.

Instructions

Use water to keep fire-exposed containers and surfaces cool and prevent explosive rupture.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate area.

Large spill

For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapours, in accordance with good industrial hygiene practice.

Environmental

Avoid release to the environment.

Cleanup methods

Collect as much of the spilled material as possible using non-sparking tools. Place in a metal container approved for transportation by appropriate authorities. Clean up residue with an appropriate solvent selected by a qualified and authorised person.

Materials: non-sparking tools, metal container, appropriate solvent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not use in a confined area with minimal air exchange. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use. Do not breathe dust/fume/gas/mist/vapours/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid contact with oxidising agents (eg. chlorine, chromic acid etc.) Vapours may travel long distances along the ground or floor to an ignition source and flash back.

Storage

Store in a well-ventilated place. Protect from sunlight. Do not expose to temperatures exceeding 50C/122F. Store away from heat.

Hygiene

Do not eat, drink or smoke when using this product. Wash thoroughly after handling.

Fire prevention

Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide ventilated enclosure for heat curing. Curing enclosures must be exhausted to outdoors or to a suitable emission control device. Do not remain in area where available oxygen may be reduced. Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment.

Hands

Gloves made from the following material(s) are recommended: Nitrile rubber.

Eyes

Indirect vented goggles.

Respiratory

In case of inadequate ventilation wear respiratory protection. An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: Half facepiece or full facepiece air-purifying respirator suitable for organic vapours Half facepiece or full facepiece supplied-air respirator

Skin/Body

Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid. Aerosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
Colourless, solvent-like odour
Colour
Colourless
Colour Intensity
---
Form
---
Odor
solvent-like odour
Odor Threshold
No data available.
Ph
Not applicable.
Melting Point
No data available.
Boiling Point
Not applicable.
Flash Point
<=30 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available.
Vapor Pressure
500,000 - 900,000 Pa [Details:CONDITIONS: 20 - 50 deg. C]
Vapor Density
---
Relative Density
0.7 g/ml
Bulk Density
---
Density
---
Flammability
Not applicable.
Upper Explosive Limit
No data available.
Lower Explosive Limit
0.6 % volume
Explosive Limits
---
Auto Ignition Temperature
No data available.
Decomposition Temperature
No data available.
Solubility
---
Partition Coefficient
No data available.
Solubility In Water
Slight (less than 10%)
Solubility In Fat
---
Molecular Weight
---
Voc Content
100 g/l
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Reactivity

This material may be reactive with certain agents under certain conditions - see the remaining headings in this section

Hazardous reactions

Hazardous polymerisation will not occur.

Avoid

Heat. Sparks and/or flames. Temperatures above the boiling point. High shear and high temperature conditions

Incompatible

Explosive when mixed with oxidizing substances. Strong acids.

Decomposition

Hydrocarbons, Carbon monoxide, Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.1
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Scotch 1625 Contact Cleaner?

The signal word is danger.

What is the physical form of Scotch 1625 Contact Cleaner?

Scotch 1625 Contact Cleaner is a liquid. aerosol appearing as colourless, solvent-like odour with colourless color. It has solvent-like odour odor.

What is Scotch 1625 Contact Cleaner used for?

Electrical equipment cleaning

What are the hazard statements for Scotch 1625 Contact Cleaner?

This substance has 5 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container. may burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.

What is the melting point of Scotch 1625 Contact Cleaner?

The melting point is No data available. and the boiling point is Not applicable..