Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SCP-700C Cleaner
- Product Code
- 71002209, 71002210, 71002213, 71002847, 71075651
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 0Q10-F0GF-0005-98D6
Identified Uses
Ink cleaner for printing ink
Uses advised against
Use only for intended applications
Manufacturers & Suppliers
Matthews Marking System
manufacturer
Zona Franca La Lima, Multitenant #8, Cartago, Costa Rica 30106
(506) 4000-1103
http://matthewsmarking.com
Matthews Marking Systems, Germany
Porschestr. 1a, Estenfeld, Germany D-97230
49 8052 95110
http://matthewsmarking.com
Emergency Contacts
Emergency Contact
112
24 Hours (EU excluding UK and Germany)
Chemtrec
1-703-527-3887
24 Hours (World including UK and Germany)
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove person to fresh air and place in a position comfortable for breathing. Keep person at rest. If breathing is difficult, administer oxygen. If breathing has stopped, provide artificial respiration. If symptoms develop or persist, seek medical advice/attention.
Symptoms: Drowsiness, dizziness, headache, nausea, lowering of consciousness, respiratory distress, confusion, unconsciousness.
Remove contaminated clothing and shoes. Rinse skin with copious amounts of water [shower] for several minutes. Launder contaminated clothing before reuse. If symptoms develop or persist, seek medical advice/attention.
Rinse eyes with plenty of water for several minutes. Remove contact lenses if present and easy to do so. Protect unexposed eye. If symptoms develop or persist, seek medical advice/attention. Rinse eyes with plenty of gently flowing lukewarm water for 15 minutes. Remove contact lenses if present and easy to do so. Protect unexposed eye. If symptoms develop or persist, seek medical advice/attention.
Symptoms: Irritation, redness, pain, inflammation, itching, burning and tearing.
If swallowed, DO NOT induce vomiting unless told to do so by a physician or poison control center. Rinse mouth with water. Never give anything by mouth to an unconscious person. If spontaneous vomiting occurs, place on the left side with head down to prevent aspiration of liquid into the lungs. If symptoms develop or persist, seek medical advice/attention.
Immediate Medical Attention
Skin/eye burns require immediate treatment. Overexposure via inhalation requires urgent medical treatment.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water mist/fog, carbon dioxide, dry chemical or alcohol resistant foam.
Do not use water jet.
Highly flammable liquid. Will be easily ignitable by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Inhalation or contact with material may irritate or burn skin and eyes. Fire may produce irritating, corrosive and/or toxic gases. Vapors may cause dizziness or suffocation.
Fight fire from a maximum distance. Move containers from fire area if you can do it without risk. Use water spray/fog for cooling fire exposed containers. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. Always stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles. If this is impossible, withdraw from area and let fire burn. Stand by, at a safe distance, with extinguisher ready for possible re-ignition. A vapor-suppressing foam may be used to reduce vapors. Do not handle damaged containers unless specialized to do so.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full-face piece operated in positive pressure mode. Avoid contact with skin, eyes, hair and clothing. Do not breathe fumes/gas/mists/aerosols/vapors/dusts.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Ventilate area. Extinguish any sources of ignition. All equipment used when handling the product must be grounded. Wear recommended personal protective equipment (see Section 8). Avoid contact with skin, eyes and clothing. Avoid breathing mist, vapor, dust, fume and spray. Do not walk through spilled material. Wash thoroughly after handling.
Prevent further leakage or spillage if safe to do so. Discharge into the environment must be avoided.
Contain and collect spillage and place in suitable container for future disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use appropriate personal protective equipment (see Section 8). Use only with adequate ventilation. Avoid breathing mist/vapor/spray/dust. Do not eat, drink, smoke, or use personal products when handling chemical substances. Avoid contact with skin, eyes and clothing. Wash affected areas thoroughly after handling. Keep away from incompatible materials (See Section 10). Keep containers tightly closed when not in use.
Keep containers tightly closed when not in use.
Do not eat, drink, smoke, or use personal products when handling chemical substances. Wash affected areas thoroughly after handling.
Store away from heat, open flames and other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Emergency eye wash stations and safety showers should be available in the immediate vicinity of use or handling. Provide adequate ventilation to maintain the airborne concentrations of vapor, mists, and/or dusts below the applicable workplace exposure limits, while observing recognized national standards (or equivalent).
Chemical resistant, impervious gloves approved by the appropriate standards. Gloves must be inspected prior to use. Avoid skin contact with used gloves. Appropriate techniques should be used to remove used gloves and contaminated clothing.
Safety glasses or goggles. Use eye protection equipment that has been tested and approved by recognized national standards (or equivalent).
If engineering controls do not maintain airborne concentrations below the applicable workplace exposure limits, or to an acceptable level (if exposure limits have not been established), a respirator approved by recognized national standards (or equivalent) must be worn.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Ensure that all personal protective equipment is approved by recognized national standards (or equivalent).
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended handling and storage conditions.
Not reactive under recommended handling and storage conditions.
Hazardous reactions are not anticipated under recommended conditions of handling and storage.
Extreme heat, open flames, hot surfaces, sparks, ignition sources, static electricity and incompatible materials. Vapor accumulation in low or confined areas.
None known.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Based on available data, the classification criteria are not met.
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
Product data: No data available.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The product does not contain any substances assessed to be PBT or vPvB. Both 2-Butanone and Propan-2-ol are assessed as not being PBT or vPvB.
12.6 Endocrine disrupting properties
No data available.
12.7 Other adverse effects
No data available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Not determined or not available.
Not determined or not available.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- Flammable liquid, N.O.S.
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Not determined.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SCP-700C Cleaner?
The signal word is danger.
What is the physical form of SCP-700C Cleaner?
SCP-700C Cleaner is a colorless liquid with not determined or not available. color. It has ketonic odor.
What is the solubility of SCP-700C Cleaner?
Soluble in the following materials: Ketones, Alcohols. Slightly soluble in water.
What is SCP-700C Cleaner used for?
Ink cleaner for printing ink
What are the hazard statements for SCP-700C Cleaner?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour
- H319: Causes serious eye irritation
- H336: May cause drowsiness or dizziness
What is the melting point of SCP-700C Cleaner?
The melting point is -86°C/-123°F and the boiling point is 79°C/147°F.