NextSDS Logo
Safety Data Sheet EN

15-Acetyldeoxynivalenol

CAS 88337-96-6

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
15-Acetyldeoxynivalenol
Product Code
32928

Regulatory Identifiers

CAS Number
88337-96-6 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich

manufacturer

S

Sigma-Aldrich BVBA/SPRL

manufacturer

Pegasuslaan 5, B-1831 DIEGEM

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 2 H300
Acute Tox. Cat. 3 H331
Acute Tox. Cat. 3 H311

GHS Pictograms

GHS06 - Acute toxicity

GHS06

Hazard Statements

H300 Fatal if swallowed.
H311 + H331 Toxic in contact with skin or if inhaled.

Precautionary Statements

P280 Wear protective gloves/ protective clothing.
P304 + P340 + P311 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor.
IF SWALLOWED: Immediately call a POISON CENTER/doctor. Rinse mouth.
IF ON SKIN: Wash with plenty of water. Call a POISON CENTER/doctor if you feel unwell.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
(3α,7α)- 15-(Acetyloxy)-12,13-epoxy-3,7-dihydroxy-trichothec-9-en-8-one 88337-96-6 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Skin contact

Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.

Eye contact

Flush eyes with water as a precaution.

Ingestion

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific hazards

Carbon oxides. Combustible.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear respiratory protection. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up and arrange disposal without creating dust. Sweep up and shovel.

Materials: suitable, closed containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols.

Storage

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

Eyes

Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Environmental

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
solid
Odor
No data available
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
No data available
Bulk Density
---
Density
---
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
no data available
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No data available

Hazardous reactions

No data available

Avoid

No data available

Incompatible

Strong oxidizing agents

Decomposition

Hazardous decomposition products formed under fire conditions. - Carbon oxides. Other decomposition products - No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
2811
Shipping Name
TOXIC SOLID, ORGANIC, N.O.S. ((3α,7α)- 15-(Acetyloxy)-12,13-epoxy-3,7-dihydroxy-trichothec-9-en-8-one)
Transport Class
6.1
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 15-Acetyldeoxynivalenol?

The signal word is danger.

What is the physical form of 15-Acetyldeoxynivalenol?

15-Acetyldeoxynivalenol is a solid . It has no data available odor.

What is 15-Acetyldeoxynivalenol used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for 15-Acetyldeoxynivalenol?

This substance has 2 hazard statements:

  • H300: Fatal if swallowed.
  • H311 + H331: Toxic in contact with skin or if inhaled.

What is the melting point of 15-Acetyldeoxynivalenol?

The melting point is No data available and the boiling point is No data available.