Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ANTIFREEZE
- Product Code
- BSA001, BSA002, BSA005, BSA025, NBS001, NBS002, SFD127, BSA199, SAG001, SAG002, SAG005, SAG025, SAG199, GFA025, DRP001, DRP002, DRP005, DRP025, DRP199
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
TETROSYL LIMITED
manufacturer
BEVIS GREEN WORKS, WALMERSLEY, BURY, BL9 6RE
0161 764 5981
Emergency Contacts
Emergency Contact
0161 764 5981
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| DISODIUM TETRABORATE PENTAHYDRATE EC: 215-540-4 | 12179-04-3 | 1 - 5% | Yes |
| MONO ETHYLENE GLYCOL EC: 203-473-3 | 107-21-1 | 60 - 100% | Yes |
Notes
The data shown are in accordance with the latest EC Directives.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move injured person into fresh air and keep person calm under observation. If necessary, seek hospital and bring these instructions.
Symptoms: Irritation of nose, throat and airway.
Remove affected person from source of contamination. Remove contaminated clothing and flush with plenty of water until pain disappears. If discomfort persists transport to hospital and bring these instructions.
Symptoms: Prolonged skin contact may cause redness and irritation.
Immediately flush with plenty of water for up to 15 minutes. Remove any contact lenses and open eyes wide apart. Get medical attention if any discomfort continues.
Symptoms: Irritation, burning, lachrymation, blurred vision after liquid splash.
Immediately rinse mouth and drink plenty of water. Keep person under observation. If person becomes uncomfortable take to hospital along with these instructions.
Symptoms: May cause discomfort if swallowed. Ingestion may result in unconsciousness, blindness and death. Central nervous system depression.
Immediate Medical Attention
If in doubt, GET MEDICAL ATTENTION PROMPTLY!
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire-extinguishing media appropriate for surrounding materials.
Do not use water jet as an extinguisher, as this will spread the fire.
No unusual fire or explosion hazards noted.
No specific fire fighting procedure given.
Firefighter Protection
Leave danger zone immediately.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In case of spills, beware of slippery floors and surfaces.
The product should not be dumped in nature but collected and delivered according to agreement with the local authorities.
Absorb spillage with non-combustible, absorbent material
Materials: non-combustible, absorbent material
Related Products
Similar products with comparable safety profiles
ETHYLENE GLYCOL, ANTIFREEZE GRADE
CAS: 107-21-1
FREEZER
UFI: 2581-P30W-000V-7N39
INDUSTRIAL SUPREME - ALL WEATHER PROTECTION LOW CONDUCTIVITY ANTIFREEZE/ COOLANT
---
ZEP ANTI-RUST
---
FREEZCOOL RED
UFI: A3KE-NEX7-VMGV-VKXG
ASSA LOCK CLEANER DE-ICER
---
Eurol Antifreeze G11
UFI: HDYX-Y24E-EA0N-XWDF
Liebherr Antifreeze OS Concentrate
UFI: H710-80G4-X00Q-3VM9
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Read and follow manufacturer's recommendations. Always remove grease with soap and water or skin cleaning agent, never use organic solvents. Good personal hygiene is necessary. Wash hands and contaminated areas with water and soap before leaving the work site. Do not eat, drink or smoke when using the product.
Store in tightly closed original container in a dry, cool and well-ventilated place.
Good personal hygiene is necessary. Wash hands and contaminated areas with water and soap before leaving the work site. Do not eat, drink or smoke when using the product.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use engineering controls to reduce air contamination to permissible exposure level. Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.
Protective gloves and goggles must be used if there is a risk of direct contact or splash.
Wear tight-fitting goggles or face shield.
Wear suitable respiratory protection.
Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact. Wear apron or protective clothing in case of contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No particular stability concerns.
Reaction with: Oxidising materials.
Not determined.
Avoid excessive heat for prolonged periods of time. Avoid heat, flames and other sources of ignition.
Acids, oxidising.
In case of fire, toxic gases (CO, CO2, NOx) may be formed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ANTIFREEZE?
The signal word is na: r-phrases.
What is the physical form of ANTIFREEZE?
ANTIFREEZE is a liquid appearing as liquid with blue. color. It has odourless. odor.
What is the solubility of ANTIFREEZE?
Miscible with: Acetone Alcohol Miscible with water
What is the melting point of ANTIFREEZE?
The melting point is Scientifically unjustified. -12°C and the boiling point is 165°C 760 mm Hg.