Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
Product Code
1.05833
Chemical Name
Magnesium chloride hexahydrate

Regulatory Identifiers

CAS Number
7791-18-6 Check regulations →
REACH No.
01-2119485597-19-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

distributor

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Formula : MgCl2 · 6H2O Molecular weight : 203,30 g/mol CAS-No. : 7791-18-6 EC-No. : 232-094-6

Chemical Name CAS Number Concentration Hazardous
MgCl2 · 6H2O EC: 232-094-6 7791-18-6 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Hydrogen chloride gas, Magnesium oxide. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry. Recommended storage temperature see product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves.

Eyes

Safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Required when dusts are generated. Recommended Filter type: Filter type P1. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Freezing Point
---
Solubility
---
Metal Corrosion
---
Flammability
The product is not flammable.
Partition Coefficient
Not applicable for inorganic substances
Cloud Point
---
Physical State
solid
Vapor Pressure
No data available
Melting Point
Melting point: 116,7 °C
Relative Evaporation Rate
---
Ph
No data available
Evaporation Rate
---
Voc Content
---
Colour
colorless
Colour Intensity
---
Upper Explosive Limit
No data available
Flash Point
Not applicable
Solidification Point
---
State Under Standard Conditions
---
Odor Threshold
---
Auto Ignition Temperature
No data available
Properties Status
---
Form
---
Odor
No data available
Relative Density
No data available
Softening Point
---
Bulk Density
---
Solubility In Fat
---
Crystallisation Point
---
Dynamic Viscosity
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Molecular Weight
---
Solubility In Water
468,7 g/l at 20 °C - OECD Test Guideline 105
Density
1,570 g/cm3 at 20 °C
Decomposition Temperature
No data available
Vapor Density
---
Physical State Data
solid
Appearance
---
Kinematic Viscosity
No data available
Boiling Point
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature) .

Reactivity

No data available

Hazardous reactions

no information available

Avoid

no information available

Incompatible

no information available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The signal word is no signal word.

What is the physical form of Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a solid with colorless color. It has no data available odor.

What is Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?

Reagent for analysis

What is the melting point of Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The melting point is Melting point: 116,7 °C and the boiling point is No data available.