Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
- Product Code
- 1.05833
- Chemical Name
- Magnesium chloride hexahydrate
Regulatory Identifiers
- CAS Number
- 7791-18-6 Check regulations →
- REACH No.
- 01-2119485597-19-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Merck Life Science BV/SRL
distributor
Brusselsesteenweg 288, B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Formula : MgCl2 · 6H2O Molecular weight : 203,30 g/mol CAS-No. : 7791-18-6 EC-No. : 232-094-6
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| MgCl2 · 6H2O EC: 232-094-6 | 7791-18-6 | --- | No |
Notes
No components need to be disclosed according to the applicable regulations.
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Hydrogen chloride gas, Magnesium oxide. Ambient fire may liberate hazardous vapours.
Suppress (knock down) gases/vapors/mists with a water spray jet.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Magnesium chloride hexahydrate for analysis EMSURE® ACS, ISO, Reag. Ph Eur
CAS: 7791-18-6
Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 10035-04-8
Magnesium sulfate anhydrous for analysis EMSURE®
---
Sodium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7647-14-5
Sodium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7647-14-5
Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 12125-02-9
Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 12125-02-9
Iron(III) chloride hexahydrate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 10025-77-1
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Dry. Recommended storage temperature see product label.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves.
Safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Required when dusts are generated. Recommended Filter type: Filter type P1. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
No data available
no information available
no information available
no information available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
The signal word is no signal word.
What is the physical form of Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a solid with colorless color. It has no data available odor.
What is Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?
Reagent for analysis
What is the melting point of Magnesium chloride hexahydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
The melting point is Melting point: 116,7 °C and the boiling point is No data available.