NextSDS Logo
Safety Data Sheet EN

Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur

CAS 10035-04-8

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur
Product Code
1.02382, 102382

Regulatory Identifiers

CAS Number
10035-04-8 Check regulations →
REACH No.
01-2119494219-28-XXXX

Identified Uses

Reagent for analysis, Chemical production

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

national supplier

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P280 Wear eye protection/ face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical advice/ attention.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Calcium chloride dihydrate EC: 233-140-8 10035-04-8 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Fire may cause evolution of: Hydrogen chloride gas. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
---
Odor
odorless
Odor Threshold
---
Ph
4,5 - 9,2 at 50 g/l at 20 °C
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0,01 hPa at 20 °C
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1,85 g/cm³ at 20 °C
Flammability
The product is not flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not applicable for inorganic substances
Solubility In Water
745 g/l at 20 °C - (anhydrous)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Exothermic reaction with: boron trifluoride, vinylmethyl ether, Water. Generates dangerous gases or fumes in contact with: Metals, Zinc

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Toxicity to fish static test LC50 - Pimephales promelas (fathead minnow) - 4.630 mg/l - 96 h (US-EPA) Remarks: (anhydrous substance) (ECHA) The value is given in analogy to the following substances: calcium chloride

12.1 Toxicity

Toxicity to daphnia and other aquatic invertebrates static test EC50 - Daphnia magna (Water flea) - 2.400 mg/l - 48 h (OECD Test Guideline 202) Remarks: (anhydrous substance) (ECHA) The value is given in analogy to the following substances: calcium chloride

12.1 Toxicity

Toxicity to algae ErC50 - Pseudokirchneriella subcapitata - > 4.000 mg/l - 72 h (OECD Test Guideline 201) Remarks: (anhydrous substance) (ECHA) The value is given in analogy to the following substances: calcium chloride

12.2 Persistence and degradability

The methods for determining the biological degradability are not applicable to inorganic substances.

The methods for determining the biological degradability are not applicable to inorganic substances.

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture does not contain components considered to be PBT or vPvB at levels of 0.1% or higher.

12.6 Endocrine disrupting properties

Assessment : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

12.7 Other adverse effects

Discharge into the environment must be avoided.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

No data available

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

The signal word is warning.

What is the physical form of Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur is a solid with white color. It has odorless odor.

What is Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur used for?

Reagent for analysis, Chemical production

What are the hazard statements for Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

The melting point is No data available and the boiling point is No data available.