Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur
Product Code
1.02382
Chemical Name
Calcium chloride dihydrate

Regulatory Identifiers

CAS Number
10035-04-8 Check regulations →
REACH No.
01-2119494219-28-XXXX

Identified Uses

Reagent for analysis, Chemical production

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P280 Wear eye protection/ face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical advice/ attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Calcium chloride dihydrate EC: 233-140-8 10035-04-8 90 - 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Unsuitable media

Water Foam

Specific hazards

Not combustible. Fire may cause evolution of: Hydrogen chloride gas. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Cover drains. Collect, bind, and pump off spills. Take up dry. Dispose of properly. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : Nitrile rubber, Break through time : 480 min, Glove thickness : 0,11 mm, Protective index : Full contact / Splash contact, Manufacturer : KCL 741 Dermatril® L. Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
Not applicable for inorganic substances
Voc Content
---
Properties Status
---
Dynamic Viscosity
No data available
Ph
4,5 - 9,2 (20 °C)
Boiling Point
No data available
State Under Standard Conditions
---
Colour
white
Solubility
---
Upper Explosive Limit
No data available
Colour Intensity
---
Flash Point
No data available
Vapor Density
---
Vapor Pressure
0,01 hPa (20 °C)
Decomposition Temperature
No data available
Form
crystalline
Cloud Point
---
Solidification Point
---
Softening Point
---
Odor Threshold
Not applicable
Explosive Limits
---
Relative Evaporation Rate
---
Lower Explosive Limit
No data available
Physical State Data
solid
Odor
odourless
Kinematic Viscosity
No data available
Melting Point
No data available
Density
1,85 g/cm³ (20 °C)
Freezing Point
---
Molecular Weight
147,01 g/mol
Solubility In Fat
---
Evaporation Rate
No data available
Relative Density
No data available
Crystallisation Point
---
Auto Ignition Temperature
not combustible
Bulk Density
---
Physical State
solid
Metal Corrosion
---
Solubility In Water
745 g/l (20 °C) (anhydrous)
Flammability
The product is not flammable.
Appearance
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Exothermic reaction with: boron trifluoride, vinylmethyl ether, Water. Generates dangerous gases or fumes in contact with: Metals, Zinc

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

The signal word is warning.

What is the physical form of Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur is a solid with white color. It has odourless odor.

What is Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur used for?

Reagent for analysis, Chemical production

What are the hazard statements for Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of Calcium chloride dihydrate for analysis EMSURE® ACS, Reag. Ph Eur?

The melting point is No data available and the boiling point is No data available.