NextSDS Logo
Safety Data Sheet EN

Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur

CAS 7647-01-0

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur
Product Code
1.00317

Regulatory Identifiers

CAS Number
7647-01-0 Check regulations →
REACH No.
This product is a mixture. REACH Registration Number see section 3.

Identified Uses

Reagent for analysis, Chemical production

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Met. Corr. Cat. 1 H290
Skin Corr. Cat. 1B H314
Eye Dam. Cat. 1 H318
STOT SE Cat. 3 H335

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H290 May be corrosive to metals.
H314 Causes severe skin burns and eye damage.
H335 May cause respiratory irritation.

Precautionary Statements

P234 Keep only in original packaging.
P261 Avoid breathing mist or vapors.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrochloric Acid EC: 231-595-7 7647-01-0 30 - 50% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air. Call in physician.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately.

Eye contact

After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Hydrogen chloride gas. Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up with liquid-absorbent and neutralising material (e.g. Chemizorb® H+, Merck Art. No. 101595). Clean up affected area.

Materials: liquid-absorbent and neutralising material (e.g. Chemizorb® H+, Merck Art. No. 101595)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe label precautions.

Storage

Tightly closed. Recommended storage temperature see product label.

Hygiene

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Latex gloves, Minimum layer thickness: 0,6 mm, Break through time: 120 min, Material tested: Lapren® (KCL 706 / Aldrich Z677558, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Tightly fitting safety goggles

Respiratory

Recommended Filter type: filter E-(P2). The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

acid-resistant protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
ca.1,19 g/cm3 at 20 °C
Cloud Point
---
Form
---
Solubility In Water
soluble
Solubility In Fat
---
Lower Explosive Limit
---
Decomposition Temperature
---
Flammability
---
Evaporation Rate
---
Dynamic Viscosity
2,3 mPa.s at 15 °C
Colour Intensity
---
Auto Ignition Temperature
---
Appearance
---
Kinematic Viscosity
No data available
Physical State
liquid
Vapor Pressure
190 hPa at 20 °C
Relative Density
No data available
Ph
< 1 at 20 °C
Vapor Density
---
Melting Point
Solidification point: -30 °C
Upper Explosive Limit
---
Flash Point
Not applicable
Solidification Point
---
Properties Status
---
Molecular Weight
---
Freezing Point
---
State Under Standard Conditions
---
Odor
stinging
Relative Evaporation Rate
---
Bulk Density
---
Metal Corrosion
---
Voc Content
---
Explosive Limits
---
Odor Threshold
---
Colour
colorless
Crystallisation Point
---
Solubility
---
Softening Point
---
Partition Coefficient
Not applicable
Physical State Data
liquid
Boiling Point
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Corrosive in contact with metals

Hazardous reactions

Exothermic reaction with: Amines, potassium permanganate, salts of oxyhalogenic acids, semimetallic oxides, semimetallic hydrogen compounds, Aldehydes, vinylmethyl ether. Risk of ignition or formation of inflammable gases or vapours with: Carbides, lithium silicide, Fluorine. Generates dangerous gases or fumes in contact with: Aluminum, hydrides, Formaldehyde, Metals, strong alkalis, Sulfides. Risk of explosion with: Alkali metals, conc. sulfuric acid.

Avoid

Heating.

Incompatible

Metals, metal alloysGives off hydrogen by reaction with metals.

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1789
Shipping Name
HYDROCHLORIC ACID
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The signal word is danger.

What is the physical form of Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a liquid with colorless color. It has stinging odor.

What is Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?

Reagent for analysis, Chemical production

What are the hazard statements for Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

This substance has 3 hazard statements:

  • H290: May be corrosive to metals.
  • H314: Causes severe skin burns and eye damage.
  • H335: May cause respiratory irritation.

What is the melting point of Hydrochloric acid fuming 37% for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The melting point is Solidification point: -30 °C and the boiling point is No data available.