NextSDS Logo
Safety Data Sheet EN

Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP

CAS 107-21-1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP
Product Code
1.09621
Chemical Name
Ethylene glycol

Regulatory Identifiers

CAS Number
107-21-1 Check regulations →
REACH No.
01-2119456816-28-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Millipore

manufacturer

M

Merck Life Science BV/SRL

distributor

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
STOT RE Cat. 2 H373

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed.
H373 May cause damage to organs (Kidney) through prolonged or repeated exposure if swallowed.

Precautionary Statements

P260 Do not breathe mist or vapors.
P264 Wash skin thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P301 + P312 IF SWALLOWED: Call a POISON CENTER/ doctor if you feel unwell.
P314 Get medical advice/ attention if you feel unwell.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
ethylene glycol EC: 203-473-3 107-21-1 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air. Call in physician.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water Foam Carbon dioxide (CO2) Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.

Instructions

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Recommended storage temperature see product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Upper Explosive Limit
15,3 %(V)
Colour Intensity
---
Cloud Point
---
Kinematic Viscosity
---
Solubility
---
Freezing Point
---
Odor Threshold
---
Flammability
---
Evaporation Rate
---
Colour
colorless
Boiling Point
197,4 °C
Flash Point
115 °C - open cup
Ph
---
Properties Status
---
Explosive Limits
---
Physical State Data
liquid
Decomposition Temperature
---
Physical State
liquid
Odor
odorless
Auto Ignition Temperature
412 °C
Partition Coefficient
log Pow: -1,36 - Bioaccumulation is not expected. n-octanol/water
Metal Corrosion
---
Softening Point
---
Solidification Point
---
Voc Content
---
Relative Evaporation Rate
---
State Under Standard Conditions
---
Dynamic Viscosity
---
Lower Explosive Limit
3,2 %(V)
Form
---
Relative Density
---
Solubility In Water
completely miscible
Crystallisation Point
---
Density
1,113 g/cm3 at 20 °C
Bulk Density
---
Melting Point
-13 °C
Molecular Weight
---
Appearance
---
Vapor Pressure
1 hPa at 51,1 °C
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.

Hazardous reactions

Risk of explosion with: Aluminum, perchloric acid. Risk of ignition or formation of inflammable gases or vapours with: chromyl chloride, Strong oxidizing agents, chlorates, Peroxides, potassium permanganate. Exothermic reaction with: chlorosulfonic acid, Sodium hydroxide, fuming sulfuric acid, sulfuric acid

Avoid

Strong heating.

Incompatible

various plastics, Strong oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?

The signal word is warning.

What is the physical form of Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?

Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP is a liquid with colorless color. It has odorless odor.

What is Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP used for?

Reagent for analysis

What are the hazard statements for Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?

This substance has 2 hazard statements:

  • H302: Harmful if swallowed.
  • H373: May cause damage to organs (Kidney) through prolonged or repeated exposure if swallowed.

What is the melting point of Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?

The melting point is -13 °C and the boiling point is 197,4 °C.