Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP
- Product Code
- 1.09621
- Chemical Name
- Ethylene glycol
Regulatory Identifiers
- CAS Number
- 107-21-1 Check regulations →
- REACH No.
- 01-2119456816-28-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Millipore
manufacturer
Merck Life Science BV/SRL
distributor
Brusselsesteenweg 288, B-3090 OVERIJSE
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethylene glycol EC: 203-473-3 | 107-21-1 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water Foam Carbon dioxide (CO2) Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Methanol for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-56-1
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanol absolute for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 64-17-5
Ethanolamine for analysis EMSURE®
CAS: 141-43-5
Isoamyl alcohol for analysis EMSURE® ACS,Reag. Ph Eur
CAS: 123-51-3
DIISOPROPYL ETHER FOR ANALYSIS EMSURE® ACS, REAG. PH EUR
CAS: 108-20-3
1-Propanol for analysis EMSURE® ACS,Reag. Ph Eur
CAS: 71-23-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Recommended storage temperature see product label.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
Risk of explosion with: Aluminum, perchloric acid. Risk of ignition or formation of inflammable gases or vapours with: chromyl chloride, Strong oxidizing agents, chlorates, Peroxides, potassium permanganate. Exothermic reaction with: chlorosulfonic acid, Sodium hydroxide, fuming sulfuric acid, sulfuric acid
Strong heating.
various plastics, Strong oxidizing agents
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?
The signal word is warning.
What is the physical form of Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?
Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP is a liquid with colorless color. It has odorless odor.
What is Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP used for?
Reagent for analysis
What are the hazard statements for Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?
This substance has 2 hazard statements:
- H302: Harmful if swallowed.
- H373: May cause damage to organs (Kidney) through prolonged or repeated exposure if swallowed.
What is the melting point of Ethylene glycol for analysis EMSURE® Reag. Ph Eur,Reag. USP?
The melting point is -13 °C and the boiling point is 197,4 °C.